Intended Use / Foreseeable Misuse; Obligation Of The Operator Before Start-Up; Personnel Qualification; Obligations; Organisational Measures - HYDAC ELECTRONIC HAT 1425 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6

2.2 Intended use / foreseeable misuse

Claims for defects or liability, regardless of the legal foundation, do not apply with
incorrect or improper installation, commissioning, usage, handling, storage, maintenance,
repair, use of unsuitable components or other circumstances, which the manufacturer is
not responsible for.
The manufacturer assumes no responsibility for determining the interfaces for installation
in a system or the installation, use or functionality of the product in this system.

2.3 Obligation of the operator before start-up

In accordance with the EC Machinery Directive, the measuring system of a component
E
is considered to be a machine part for the installation into a system/machine. Moreover,
the conformity of the measuring system was investigated in respect of the EMC
Directive.
It is therefore only permitted to start up the measuring system if it has been established
that the system/machine into which the measuring system is to be fitted, satisfies the
provisions of the EC Machinery Directive, the EC EMC Directive, the harmonised
standards, European standards or the corresponding national standards.

2.4 Personnel qualification; obligations

 All work on the measuring system must be carried out by qualified personnel only.
Qualified personnel includes persons, who, through their training, experience and
instruction, as well as their knowledge of the relevant standards, provisions, accident
prevention regulations and operating conditions, were authorised by the persons
responsible for the system to carry out the required work and are able to recognise and
avoid potential hazards.
 The definition of "Qualified Personnel" also includes an understanding of the standards
VDE 0105-100 and IEC 364 (source: e.g. Beuth Verlag GmbH, VDE-Verlag GmbH).
 Define clear rules of responsibilities for the assembly, installation, start-up and
operation. It is obligatory to provide supervision for trainee personnel!

2.5 Organisational measures

 The user manual must always be kept accessible at the place of use of the measuring
system.
 In addition to the user manual, generally applicable legal and other binding accident
prevention and environmental protection regulations must be paid attention to and must
be mediated.
 The respective applicable national, local and system-specific provisions and
requirements must be paid attention to and mediated.
 It is mandatory for the operator to inform personnel on special operating features and
requirements.
 The personnel instructed to work with the measuring system must have read and
understood the user manual, especially the chapter "Basic safety instructions" prior to
commencing work.
 The nameplates and any prohibition or instruction symbols applied on the measuring
system must always be maintained in a legible state.
 Repairs may only be undertaken by the manufacturer or a facility or person authorised
by the manufacturer.
Edition: 2021-02-22
HYDAC ELECTRONIC GMBH
HAT 1425 CANopen Safety
Part No.: 670047

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hat 1425 canopen

Table des Matières