Control Of The Number Of Manoeuvres Performed; Manoeuvre Counter Reset; 11 7.5 Connection Of Other Devices - Nice Robus 600 Instructions Et Avertissements Pour L'installateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Control of the number of manoeuvres performed

The number of manoeuvres performed as a percentage on the set limit can be verified by means of the "Maintenance warning" function. Fol-
low the indications in table 17 for this control.
Tabella 17: control of the number of manoeuvres performed
Press the key [Set] and hold it down (approx. 3 s)
1.
Release the [Set] key when L1 LED starts flashing
2.
Press key [▲] or [▼] to move the flashing LED onto the input LED L7
3.
representing the "Maintenance warning" parameter
Press the key [Set],and hold it down during step 5, 6 and 7
4.
Wait approx. 3 seconds, after which the LED representing the current
5.
level of the parameter "Maintenance warning" will light up
Press and immediately release the [▲] and [▼] keys.
6.
The LED that corresponds to the selected level flashes. The number of flashes indicates the percentage
7.
of manoeuvres performed(in multiples of 10%) in relation to the set limit.
For example: with the maintenance warning set on L6 being 10000, 10% is equal to 1000 manoeuvres;
if the LED flashes 4 times, this means that 40% of the manoeuvres have been reached (being between
4000 and 4999 manoeuvres). The LED will not flash if 10% of the manoeuvres hasn't been reached.
Release the key [Set]
8.

Manoeuvre counter reset

After the maintenance of the system has been performed the manoeuvre counter must be reset. Proceed as described in table 18.
Table 18: manoeuvre counter reset
Press the key [Set] and hold it down (approx. 3 s)
1.
Release the [Set] key when L1 LED starts flashing
2.
Press key [▲] or [▼] to move the flashing LED onto the input LED L7 representing the
3.
"Maintenance warning" parameter
Press the key [Set], and hold it down during step 5 and 6
4.
Wait approx. 3 seconds, after which the LED representing the current
5.
level of the parameter "Maintenance warning" will light up.
Press keys [▲] and [▼], hold them down for at least 5 seconds and then release them.
6.
The LED that corresponds to the selected level flashes rapidly indicating that the
manoeuvre counter has been reset
Release the key [Set]
7.
7.5 Connection of Other Devices
If the user needs to feed external devices such as a proximity read-
er for transponder cards or the illumination light of the key-operated
selector switch, it is possible to tap power as shown in Figure 27.
The power supply voltage is 24Vdc -30% - +50% with a maximum
available current of 100mA.
20
-
27
Example
SET
L1
SET
or
SET
3s
and
....
SET
Example
SET
L1
SET
or
L7
SET
3s
and
SET
+
24Vcc
3s
L7
n=?
3s

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Robus 600pRobus 1000Robus 1000pRobus 400

Table des Matières