Connections - Robert Juliat TOPAZE 1119 CS Dossier Technique

Masquer les pouces Voir aussi pour TOPAZE 1119 CS:
Table des Matières

Publicité

DESCRIPTION.
A
1200W Cold strike follow spot.
c Lighting unit's power cable.
Cable H07 RN-F 4G 1,5mm
with a 3 point + E, P17 male plug.
B
Power supply unit (P.S.U.)
Refer to section A - 9.
Before connecting to the mains.
- Check the power conformity; P.S.U. power 1 conform with lamp power : 1200W.
- Check the voltage conformity with the mains: 230V/50Hz or 245/50Hz or 208/60Hz.
Untighten the screw 3 .
Turn the switch 4 to select the appropriate voltage.
Then tighten the screw 3 .
Lighting unit / Power supply connection.
- Connect the lighting unit's A power cable C to the P.S.U. B .
- Place the lamp into position - refer to section A - 9.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lamp house's bonnet when the
lighting unit is on.
- Never connect to a dimmable channel.
- Use only when lamp in place.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
1200W MSD COLD STRIKE FOLLOW SPOTS

CONNECTIONS.

A
c
2
length 3m fitted
TECHNICAL FILE
2
1119 CS & CCS
1419 CS & CCS
Section A - 5
Each time you switch on: make sure the
fan is working correctly.
For 208/230/245V version.
230V.
50Hz
208V.
60Hz
B
1
245V.
50Hz
3
4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Topaze 1119 ccsManon 1419 csManon 1419 ccs

Table des Matières