Connections - Robert Juliat 900 SNX Dossier Technique

Projecteurs de decoupes msr 1200/2500w reamorcage a chaud
Table des Matières

Publicité

CONNECTIONS.

Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 10 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lamp cable
ballast and connector e
- Connect the cable D to the connector ( d ) of the
ballast and to the connector
- Place the lamp into position - refer to section A - 7.
- Connect the DATA line on connector ( a ) "XLR5" or
the analog command to the the connector ( c ) "XLR4".
( For the connection configurations : refer to section B - 3 ).
- Connect the optional units that are possible, to connector g
( Only DATA ).
- Plug the cable 8 to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the circuit breaker
protection 4 is well engaged.
- If you use the optional outlet 5 , engage the circuit breaker 2 .
- Lock the cable C in the clips i .
WARNING !
- Never open the lamp house bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when bulb is in place.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W & 2500W MSR PROFILES
A
h
e
C
f
g
C to the connector
7 of the
to the lighting unit.
f of the lighting unit "XLR7".
3 and check that the CAD 900
Each time you switch on: make sure
the fans are working correctly.
B
DATA in.
DESCRIPTION.
A 900 SNX Motorized shutter - CAD 900 version.
e - EM HARTING 16 x 16A power socket.
f - EM XLR7 shutter + DATA (option).
g - EF XLR5 output DATA (colour changer option).
h - EF mains output 220/240V (colour changer option).
B Power supply unit.
1 - Mains checklight.
2 - 6A automatic breaker.
3 - General 16A circuit breaker for 1200W.
General 25A circuit breaker for 2500W.
4 - 1A automatic breaker.
6 - Ventilation opening
7 - EF HARTING 16 x 16A - 2 latch connector.
8 -
Mains cable 3G x 1,5mm (3m) + FM 10/16A. (1200W).
Mains cable 3G x 4mm (3m) + FM P17 2P+T 32A. (2500W).
9 - CAD 900 local controls.
C A D 900
C A D 900
0/10V - DMX 512 - AVAB
a - EM XLR5 : DATA input.
b - EF XLR5 : DATA output.
ERROR
SELECT
EXIT
+
DATA
EXT. DIGI.
LOCK
EXT.
LOCAL
c - EM XLR4 : 0/+10V. input.
RESET
a b c d
d - EF XLR7 : lighting unit output.
DATA
0/10V
CONTROL
SHUTTER
10 - Rating plate.
11 - Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm length 3m fitted
with 16 x 16A M/F HARTING connectors.
D Shutter cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR7 M/F connector.
900 SNX
Section A - 5
OPTION
DMX colour
changer.
0/+10V. line.
DATA out.
(DON'T OBSTRUCT THE AIR GAPS).

Publicité

Table des Matières
loading

Table des Matières