Installation and connection (continued)
Supporting rod made of non-magnetizable material
Fig. 4-8: Example 2, transducer installed with supporting rod
4.4

Electrical connection

The BTL is attached via connectors (see Accessories on
page 20).
Note the information on shielding and cable
routing on page 13.
4.4.1
Connecting the supply voltage, control and
data signals
The connection assignments are shown in Tab. 4-2 and
Fig. 4-9.
Pin
Control and data signals
1
CAN_GND
4
CAN_H
5
CAN_L
Pin
Supply voltage (external)
3
0 V (GND)
2
+24 V
1)
1)
Please note that 24 V must be applied here and not 5 V as used for CAN
drivers.
Tab. 4-2:
BTL5-H1...C001 (BUS IN/OUT) connection assignments
1
4
2
5
3
BUS OUT
Fig. 4-9: CAN (BUS IN/OUT) pin assignments
The pin assignment for the analog connection is
shown on page 11.
10
english
Magnet
(e.g. BTL-P-1028-15R)
1
2
4
3
5
BUS IN
4.4.2

Connecting analog transducers

The BTL5-H1A/C/E _ -M _ _ _ _ -A/B/Y/Z(8)-C001 enables
e.g. the use of analog pressure or temperature sensors
along with the transducer. This makes it possible to easily
transfer the measured values of the analog sensors in the
CAN protocol.
The analog inputs are recorded serially and not
simultaneously. While the first channel is being read out,
the second change is being converted and vice versa.
As the analog values can only be processed by the BTL in
binary format, the analog process signal is converted into a
digital format by the BTL. The conversion time is
composed of the basic conversion time of the converter
used and the additional processing time in the
microcontroller (µC).
The analog values are shown as a fixed point number in a
two's complement (see Tab. 4-3). The algebraic sign for
the analog value is always located in bit 15.
"0" for
+
"1" for
-
Bit
15
14
Bit
2
2
15
14
value
Bit
10
9
Bit
2
2
10
9
value
Bit
5
4
Bit
2
2
5
4
value
Tab. 4-3:
Assignment of the analog values
The analog values shown in the current and voltage
measuring ranges can be found in Tab. 4-5 on page 12.
13
12
11
2
2
2
13
12
11
8
7
6
2
2
2
8
7
6
3
2
1
2
2
2
3
2
1