BTL5-H1A/C/E _ -M _ _ _ _ -A/B/Y/Z(8)-C001
Micropulse Transducer - Rod Style
6
Technical data
6.1
Accuracy
The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R or BTL-P-1014-2R magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
Resolution:
Position
adjustable via SDO
in 5 µm increments
Speed
adjustable via SDO
in 0.1 mm/s increments
Measured data rate f
Standard
Non-linearity
Hysteresis
Reproducibility
Temperature coefficient
(resolution + hysteresis)
6.2
Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Pressure rating (when
installed in hydraulic
cylinders)
With Ø 8 mm
With Ø 10.2 mm
Shock load
per IEC 60068-2-27
1)
Continuous shock
per IEC 60068-2-29
1)
Vibration
per IEC 60068-2-6
(note
1)
resonant frequency of the
outer rod)
Degree of protection per
IEC 60529 (when attached)
Individual specifications as per Balluff factory standard
1)
6.3
Supply voltage (external)
without analog sensors
Voltage, stabilized
BTL5-H1...
Ripple
Current draw
www.balluff.com
> 5 µm
> 0.1 mm/s
= 1 kHz
±30 µm
< 1 LSB
< 2 LSB
(6 µm + 5 ppm x nominal
length)/K
- 4 0°C to + 8 5°C
- 4 0°C to + 9 0°C
< 90%, non-condensing
< 250 bar
< 600 bar
100 g/6 ms
100 g/2 ms
12 g, 10 to 2000 Hz
IP 67
20 to 28 V DC
24 V ±2 V
ss
< 100 mA
Maximum permissible
current in a series connec-
tion
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
GND to housing
6.4
Control signals
CAN_Low, CAN_High, CAN_GND
in accordance with CiA DS 301.
Each change in status of the 4 cams is
transferred as an emergency object with the
highest priority after < 0.5 ms! This makes this
particular transducer especially suitable for
control applications where time is critical.
6.5
Analog inputs
Number of inputs
Transducer supply voltage
Conversion time
Measurement error at room
temperature
Maximum measurement
error in the operating
temperature range
Data width
Permissible input current
for current input (cut-out
limit)
Permissible input current
for voltage input
(destruction limit)
Permissible load current at
the 24 V sensor supply
1 A
< 3 A/0.5 ms
Installed
36 V
500 V DC
2 (2 current or 2 voltage
inputs)
Via 24 V DC system
voltage
Typ. 6 ms
< ±0.15% of
scale end value
< ±0.4% of
scale end value
2 x 16 bits data
40 mA
Max. 36 V continuously
160 mA continuously
english
17