BTL7-P511-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S135/KA _ _ /FA _ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
Supporting rod made of non-magnetizable material
Fig. 4-8: Example 2, transducer installed with supporting rod
4.4
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-2 to Tab. 4-4.
Note the information on shielding and cable
routing on page 12.
4.4.1
Connector S32/cable
S32
Cable color
Pin
1
YE yellow
2
GY gray
3
PK pink
4
RD red
5
GN green
6
BU blue
7
BN brown
8
WH white
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
Tab. 4-2:
Connection assignment
Fig. 4-9: Pin assignment of S32 (view of connector pins of
transducer), 8-pin M16 circular plug
www.balluff.com
Magnet
(e.g. BTL-P-1028-15R)
Interface
BTL7-P511...-S32/cable
+Init
+Start/stop
–Init
Not used
1)
–Start/stop
GND
10...30 V
Not used
1)
4.4.2
Connector S115
S115
Interface
Pin
BTL7-P511...-S115
1
+Init
2
+Start/stop
3
–Init
4
Not used
1)
5
–Start/stop
6
GND
7
10...30 V
8
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Tab. 4-3:
Connection assignment
Fig. 4-10: Pin assignment of S115 (view of connector pins of
transducer), 8-pin M12 circular plug
4.4.3
Connector S135
S135
Interface
Pin
BTL7-P511...-S135
1
–Start/stop
2
+Start/stop
3
+Init
4
–Init
5
10...30 V
6
GND
Tab. 4-4:
Connection assignment
Fig. 4-11: Pin assignment of S135 (view of connector pins of
transducer), 6-pin M16 circular plug
english
11