3. Installation
A mounting bracket is provided with the heater. The
bracket has been specifically designed to allow the prod-
uct to be fitted to a ceiling. Before drilling the holes for
the ceiling mount, please ensure that the surface is solid
and that there are no hidden water pipes or electrical
wires. The heater must be installed no less than 50 cm
from any side walls and no less than 2.4 m from the floor.
Warning: The appliance must be installed on solid sur-
faces such as concrete, wood or metal, etc.
Important: Please ensure that the supply cable is well secured so that it does not come into
contact with the reflector or trail into the heated area. The supply cable can be fixed to the
metal mounting bracket behind the heater with plastic zip ties.
1. This heater should be installed by a competent person, i.e. a qualified electrician.
2. Always disconnect the heater from the electrical supply and allow it to cool before installation.
3. When mounting on a ceiling, the lowest part of the heater must be located at or above a
minimum height of 2.4 m from ground level so that the heater cannot be touched when in
operation.
4. When mounting on a ceiling, there must be a distance of 2.4 m between your appliance and the floor.
5. When mounting on a ceiling, there must be a distance of 0.5 m between any side walls and
the appliance.
6. There must be a minimum distance of 1 m between your appliance and any living beings.
7. There must be a distance of at least 1 m between the front side of the heater and materials
such as wood, cardboard or cloth, etc.
8. When mounting on a ceiling, do not position the heater at an angle more than 90° or less
than 45°.
9. The supply cable must be at the lower end of the heater if the heater is installed at an angle
or vertically.
10. Keep the supply cord away from the body of the heater, which will get hot during use.
11. Do not install the heater on an inflammable surface.
12. Observe the minimum safe distance between the heater body and the inflammable surfaces
when mounted.
13. The heater should always have a minimum clearance of 0.5 m from the ceiling and adjacent walls.
14. If the heater is to be used outside, a weatherproof outlet is recommended.
15. Before drilling, ensure that there are no wires or water pipes in the area where the heater is
to be installed.
16. The heater must be installed on the mounting brackets provided.
17. Fasten the brackets securely to the mounting surface and to the back of the heater using the
fittings supplied.
18. Fasten the heater securely onto the brackets using the fittings supplied.
19. The brackets can be used to adjust the direction of the heater. Adjust the heater angle by
loosening the two bolts on the ceiling-mounting bracket and tighten the bolts again when
the desired angle is reached.
47