6.4

non-combustible facing material

FINISH
MATERIAL
TOP OF
APPLIANCE
WARNING: Non-combustible facing material may protrude from the top, and/or sides of this appliance,
as illustrated [up to a maximum of 6" (152.4mm)]. Greater than 6" (152.4mm) protrusions are considered a
6.5

alcove framing

NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment can
be made by increasing any or all of the height, width and depth of the enclosure.
6.6

remote receiver placement

Position the remote receiver in the valve compartment close to the electrical junction box. Ensure the
receiver is on top of the placement label, if equipped.
NON-COMBUSTIBLE
FACING MATERIAL
4" (102mm)
2" (51mm)
0" (0mm)
6" (152mm)
4" (102mm)
2" (51mm)
mantel and must meet the combustible mantel requirements.
RECESS OR
ALCOVE
AREA
APPLIANCE
APPLIANCE BASE
JUNCTION
BOX
PLACE REMOTE
RECEIVER ON TOP
OF THIS LABEL
FRONT OF
APPLIANCE
2" (51mm)
4" (102mm)
6" (152mm)
0" (0mm)
2" (51mm)
4" (102mm)
ENCLOSURE
AREA
framing
FINISH MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
1 4
W415-1345 / D / 05.01.17
EN
35

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Grandville bgd36cfntre

Table des Matières