2) GENERAL OUTLINE
The BOTTICELLI system is suitable for motorising sectional doors (fig. 3), protrud-
ing fully retracting spring-operated overhead doors (fig. 2) and counterweight
overhead doors provided with an appropriate towing arm (fig. 4). The overhead
door must not be higher than 3 metres. Its easy installation allows fast fitting
without needing the door to be modified. The irreversible gearmotor keeps the
door locked in the closing position.

3) TECHNICAL SPECIFICATIONS

3.1) Actuator
Power supply: .....................................................230V~±10%, 50/60Hz single-phase (*)
Motor voltage: ........................................................................................................................ 24V
Max. power absorbed from mains: ............................................................................. 236W
Lubrication: .................................................................................................permanent grease
Towing and pushing force: ............................................................................................. 600N
Working stroke:TRACK L.=......2900 working stroke= ..............................2400 mm(**)
...............................TRACK L.=......3500 working stroke= ............................3000 mm(***)
Average speed: ..............................................................................................................5 m/min
Impact reaction: .........................................integrated torque limiter on control panel
Manoeuvres in 24 hours: .......................................................................................................20
Limit switch: ................................................................................. Electronic with ENCODER
Courtesy light: ..............................................................................24V~ 25W max, E14 bulb
Working temperature: ...................................................................................... -15°C / +60°C
Degree of protection:..........................................................................................................IPX0
Motor head weight: .............................................................................................................. 5kg
Noise level: ....................................................................................................................<70dB(A)
Dimensions: .................................................................................................................... see fig.1
(*) Available in all mains voltages.
(**)By turning the motor head by 90° (Fig.11) the useful stroke will be 2580 mm.
(***) By turning the motor head by 90° (Fig.11) the useful stroke will be 3180 mm.
4) ACTUATOR INSTALLATION
4.1) Preliminary checks
• Check that the door is balanced.
• Check that the door slides smoothly along its entire travel.
• If the door has not been newly installed, check the wear condition of all its
components.
• Repair or replace faulty or worn parts.
• The automation reliability and safety are directly influenced by the state of
the door structure.
• Before fitting the motor, remove any superfluous ropes or chains and disable
any unnecessary appliances.
4.2) FITTING
After unpacking, dispose of the parts which make up the package properly, by
separating the different type of materials (cardboard, polystyrene, PVC,
etc.) according to the national rules in force.
1) Remove the existing locking bolt from the cremone bolt of the door.
2) In order to fix the track correctly, mark the mid-point of the door, position
the BIN on the ceiling and mark the holes (Fig. 6).
3) Drill the ceiling with a 10-dia. drill bit following the previously made marks,
and insert the Fischer plugs.
4) Secure the track at the base, fig.7 (ref.1-2) and fig.8 (ref.3-4-5).
5) With the help of an adequate support, lift the entire motor, screw the screws
onto the track-holding bracket without fixing them to the door frame
(Fig.9A) or, if the height allows it, fit the bracket to the masonry lintel by
means of plugs (Fig.9B).
6) Lift the motor-driven head until everything rests against the ceiling, and insert
the fixing screws which lock the track (including the anchoring bracket screws).
7) If the motor head and the track are not fixed directly to the ceiling, see Fig.10
(always check that the track is level and perpendicular to the ceiling).
8) In the case where the track is turned by 90° with respect to the motor head,
use the reference template in Fig. 11A to cut out the guard, keeping to the
measurements indicated. For fixing the BIN to the ceiling, see Fig.6 and in
case the track is not fixed directly to the ceiling, see Fig.12.
9) In the case where the track is made in two halves, see Fig.13; for the differ-
ent types of fixing methods, see the previous figures.
10) Release the carriage and fix the anchoring brackets to the door panel
(Fig.14). The distance allowed between track and sectional door is 108 to
166 mm. In case of greater distance, it is necessary to use the brackets and
lower the motor; in case of shorter distance, it is necessary to shorten the
towing plate.
11) Stick the adhesive labels supplied next to the dangerous points (Fig. 5).
5) CHAIN TIGHTENER ADJUSTMENT (BOTTICELLI)
The operator supplied is already calibrated and inspected. Should the chain ten-
sion need to be adjusted, proceed as shown in fig. 15.
WARNING: the anti-tear rubber element must never be completely com-
pressed. Scrupulously check that the rubber does not become totally com-
pressed during operation.
6) ELECTRICAL INSTALLATION SET-UP (Fig.16)
M)
Actuator
Ft)
Transmitter photocell
Fr)
Receiver photocells
T)
1-2-4 channel transmitter.
Arrange for the connections of accessories and safety and control devices to
reach the motor unit, keeping the mains voltage connections clearly separate
from the extra low safety voltage connections (24V) by means of the appropriate
cable holder (fig. 8 ref. 5P1).
Proceed to connection following the indications given in the wiring diagram.
The cables for connecting the accessories must be protected by a raceway (fig.
8 ref. 5C1).
INSTALLATION MANUAL
7) VENERE Control panel (Fig.17)
Supply to accessories: ........................................................................... 24V~ (180mA max)
...........................................................................................24V~ Vsafe VENERE (180mA max)
Torque limiter setting: ................................................................. on closing and opening
Automatic closing time: .................................................................................from 3 to 120s
Blinker connection: .........................................................................................24V~ max 25W
Service light switching-on time: .......................................................................................90s
Incorporated rolling-code radio receiver: ...............................frequency 433.92 MHz
Coding: ................................................................................................ rolling-code algorithm
No. combinations: ...................................................................................................... 4 milliard
Antenna impedance: ...................................................................................... 50Ohm (RG58)
Max no. radio controls to be memorised: ........................................................................10
Slow-down distance:................closing: ~24 cm ..................................opening: ~24 cm
Fuses: ....................................................................................................................... see figure 17
7.1) Terminal board connections (Fig.17)
WARNINGS - For wiring and installation operations, refer to the current
standards and good technical principles.
The wires supplied with extra low safety voltage (24V) must be kept physically
separate from the low voltage wires, or else they must be provided with adequate
additional insulation of at least 1mm.
The wires must be clamped by an extra fastener near the terminals, for example
by bands.
TERMINAL
JP6
JP7
1-2
3-4
3-5
3-6
3-7
8-9
10-11
12-13
7.2) LED (Fig.17)
The led functions are as follows:
"RADIO":Incorporated radio-receiver led.
"SET":
Limit device setting led - power ON.
7.3) DIP-SWITCH SELECTION (Fig.17)
DIP1) IBL – Locks impulses.
ON:
During the opening phase, does not accept START commands.
OFF: During the opening phase, accepts START commands.
DIP2) TEST PHOT
ON:
Enables photocell checking (5-connector photocells must be used - see
Fig.17A-).
OFF: Disables photocell checking.
7.4) TRIMMER SETTING (Fig.17)
TCA
Sets the automatic closing time, after which the gate closes automatically (can
be set from 3 to 120 sec). If the trimmer is turned all the way, the TCA is disabled.
OPENING TORQUE
Sets the ampere-stop sensitivity on opening.
CLOSING TORQUE
Sets the ampere-stop sensitivity on closing.
NOTE: In case of obstacle detection, the Ampere-stop function halts the
leaf movement, reverses the motion for 1 sec. and stays in the STOP state.
WARNING: check that the impact force value measured at the points
established by the EN 12445 standard is lower than that specified in
the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or animals,
or damage to things.
7.5) BUTTONS
"UP":
limit device setting and opening command. An autoset operation of
the torque will be performed by keeping this button pressed for 5
seconds (Fig.19).
"DOWN": limit device setting and closing command.
"OK":
radio programming.
8) LIMIT DEVICE SETTING (Fig.18)
1) Simultaneously press the "UP" and "DOWN" keys for 5 seconds. The "SET" led
blinks to indicate that the limit device setting is activated.
2) Bring the leaf to the required closing position, using the "UP" and "DOWN"
buttons on the control unit, and keeping in mind that the "DOWN" button
closes the leaf, while the "UP" button opens the leaf.
3) As soon as the leaf reaches the required closing position, press the "OK" button
in order to memorise the limit device closing position. The "SET" led confirms
data storage by blinking for 1 second.
DESCRIPTION
transformer wiring
motor wiring
Antenna input for integrated radio-receiver board
(1: BRAID. 2: SIGNAL)
START input (N.O.)
STOP input (N.C.) If not used, leave the jumper inserted.
PHOTOCELL input (N.C.) If not used, leave the jumper inserted.
FAULT input (N.O.)
Input for photocells provided with checking N.O. contact
24 V~ output for blinking light (25 W max)
24V~ 180mA max output – power supply for photocells or
other devices
24V~ Vsafe 180mA max output – power supply for checking
photocell transmitters.
13