CONTROLLER COMPONENTS
Figure 1
LCD Display:
1
+ /On & – /Off Buttons:
2
Next Button:
3
Function Dial:
4
Current Time & Date:
5
Latch Knobs:
6
Quick-release latches for hinged TM control panel.
Station Times:
7
Program Select Switch:
8
Start Times:
9
For setting the time each program cycle will start.
Water days:
10
For setting a watering day schedule for each program.
% Water Budget:
11
a program without changing program memory (Season and/or Monthly Adjust). To
the set number of programs (1–4) which can operate simultaneously. Remote Radio
Communication is also enabled or disabled in this function.
Sensor Control Switch:
12
Program Erase:
13
Manual Program Cycle:
14
cycle.
Manual Single Station:
15
Off / Rain Delay:
16
output delay for 1–7 days (Rain Delay).
Run:
17
For automatic operation.
Figure 2
Remote Port:
18
Connection port for optional remote control receiver.
Spare Fuse Holder:
19
Valve Common Terminals:
20
wires.
Valve Wire Terminals:
21
Earth Ground Lugs:
22
Terminal Strip:
23
Master Valve Terminal:
24
control wire.
Sensor Connection Terminals:
25
switch device.
Hot Post:
26
24 V a.c. output for valve zone identifi cation.
Battery Compartment:
27
Safety Fuse:
28
Replaceable 2.0A slow-blow fuse provides protection from an internal
short-circuit condition.
29 Climate Logic Weather System, CMR-Kit and R-100-Kit interface connection.
30 Top mounting hole.
31 Lower mounting hole.
2
For viewing time, program and status information.
For entry of program information.
For selection of information to be programmed or reviewed.
For selecting the programming and operating functions.
For setting the current time and date.
For setting individual watering time for each station.
For selection of programs A, B, C or D.
For the increase or decrease of station times for all stations within
To override rain switch sensor input.
For erasing information within a selected program.
For manual operation start of a selected program watering
For timed or untimed operation of a single station.
For immediate shut down of all controller output. Programmable
Holds a 2.0A slow-blow spare fuse.
For the connection of up to four fi eld (24V) common
For the connection of valve control wires.
For connection of a 6 AWG (10 mm2) copper ground wire(s).
For the connection of 120 or 230–240 V a.c. power wiring.
For the connection of a master valve or pump start relay
For the connection an optional normally-closed rain
9-volt alkaline battery access compartment.