FUSE REPLACEMENT

WARNING: If fuse replacement is required, replace only with the same type
and rating. Installing a higher amperage fuse can result in serious injury and or
equipment damage due to fi re hazard. Ensure power to controller is off prior to
removing or installing fuse.
1. Disconnect power to the controller.
2. Locate fuse (see page 3, item 27) and carefully remove it from the retaining clips.
3. Locate the replacement fuse supplied in the spare fuse holder (see page 3, item 19).
Install the new 2.0A slow-blow fuse, ensuring it is securely seated in the retaining clips.
4. Restore power to the controller.
SPECIFICATIONS
Cabinet:
Metal, weather-resistant, indoor/outdoor, wall mount with key-actuated locking cover

Dimensions:

10.5" W x 15.5" H x 5.5" D – (26.8 cm W x 39.6 cm H x 14.1 cm D)
Wiring Access Provision (conduit size):
Power Wiring - 1/2" (13 mm)
Field Wiring - 2"or 3" (51 mm or 75 mm)
Ground Wiring - 3/4" (19 mm)
Accessory Wiring - 3/4" (19 mm)
Power Specifi cations, Domestic Model:
Input – 120 V a.c., 60 Hz, 0.5A
Output – 24 V a.c., 60 Hz, 1.25A (max. total), 0.5A (max. per station)
Power Specifi cations, International Model:
Input – 230–240 V a.c., 50 Hz, 0.2A
Output – 24 V a.c., 50 Hz, 1.25A (max. total), 0.5A (max. per station)
Sensor Input:
Normally-closed rain switch (override switch provided)
Master Valve/Pump Start Relay Output:
Battery:
9-volt, Alkaline
Fuse:
250V, 2.0A, Slow-Blow (extra fuse provided)
Temperature Limit Specifi cations:
Operating – 32°F to 140°F (0°C to 60°C)
Storage – -22°F to 149°F (-30°C to 65°C)
28
24 V a.c., 0.5A (maximum)