6.9

PERCENT WEIGHING

The scale can be set to perform percent weighing.
The scale will use a mass on the platform as the 100% reference weight.
Press the [Func/Set] key to select the weighing mode.
Using the directional buttons ⭡ or ⭣, scroll through to the percentage
weighing mode, "Percent" will be shown on the display. Press [Tare/↵] to
confirm.
Once in percent weighing mode the "%" indicator will appear on the right-
hand side of the display.
Remove the sample weight. Then any other weight placed on the scale will
be displayed as a percentage of the original sample. For example, if 3500g
is placed on the scale and percent weighing is selected, the display will show
100.0%. Remove the 3500g weight and place a 3000g weight. The display
will show 85.7% as 3000g is 85.7% of 3500g.
The number of decimal points will depend on the weight used in comparison
to the capacity of the system. A smaller weight will show only "100%" while a
larger weight might show "100.00%".
If the scale was showing zero weight when entering this function, then the
user must manually enter the weight to be set as 100% as described below.
Make reference weight of 100% on platform.
Press the [Disp/Mode] key. Display will show 100%.
The weight entered must be greater than 50 scale divisions.
Press the [Func/Set] key to select a new weighing mode.
NOTE:
The display may jump by large numbers unexpectedly if small weights are used to set as
100% reference. The scale checks if the weight is too small and will show Error 7.