IP address
Indicate the network address affected to the device. An IP address is made of four
numbers separated by a dot. Each number range from 0 to 255.
DHCP identifier
►
Identifier to be used when the LEDI NETWORK TOP is configured in DHCP mode.
This identifier has 8 letters maximum. The default value is ntnnnnnn (where
nnnnnn is the serial number on 6 digits).
►
network submask
Indicate the width of the network you use. For example, a network submask
255.255.255.0 indicates that only the last number change (in the example above,
address in the network can change between 192.168.10.1 to 192.168.10.254).
Gateway address
►
If you want the LEDI NETWORK TOP to communicate with devices outside the local
network, you must indicate a gateway that will be used to go outside local network.
►
without gateway
Check this box when you don't have a gateway on your network (or don't want to use it).
B/ Product informations
Here is a description of the product informations area:
Hardware ► GT serial number
►
Display the Gorgy Timing serial number of the product. This is a 6 digits number
which is the same than the one stamped on the bottom or background of the rack.
►
Hardware ► Product code
Display the Gorgy Timing base code of the product without option (9282 for a LEDI
NETWORK TOP).
►
Ethernet Interface ► (MAC) Address
Indicate the Medium Access address of the Ethernet interface of the LEDI NETWORK
TOP.
►
Ethernet Interface ► Adapter Serial number
Indicate the serial number of the Ethernet interface of the LEDI NETWORK TOP.
This information can be useful for maintenance.
7/ If you configure several devices to communicate on the same network, you must have the same network submask.
58
MDE-LEDInetworkTOP-4092-V1.1
7