Level 1 Programming; Level 2 Functions (Settable Parameters) - Nice SOON SO2000 Instructions Et Avertissements Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34

10.2) Level 1 programming

By default level 1 function are all set to OFF, but can be modified at any time as described below. Take care during modification procedures,
as there is a maximum time interval of 10 seconds between pressing one key and another; otherwise the system exits the procedure auto-
matically memorising the changes made up to that time.
1.
Press and hold [Set] for approx. 3s
2.
Release [Set] when led L1 starts flashing.
3.
Press keys [▲] or [▼] to move the flashing led to the led associated with the function to be modified
4.
Press [Set] to change the status of the function (short flash = OFF; long flash = ON)
Wait 10s to exit the programming mode automatically after the maximum time interval.
Note: points 3 and 4 can be repeated during the same program-ming phase to set other functions to ON or OFF.

10.3) Level 2 Functions (settable parameters)

Table 4: list of programmable functions: level 2
Input Led
Parameter
L1
Pause Time
L2
Funzione P.P.
L3
Motor speed
FLASH
L4
output.ì
Motor Force
L5
on opening
Motor Force
L6
on closing
Note: "
" represents factory settings
Led (level)
L1
10 seconds
L2
20 seconds
L3
40 seconds
L4
60 seconds
L5
80 seconds
L6
120 seconds
L7
160 seconds
L8
200 seconds
L1
Open - stop - close - stop
L2
Open - stop - close- open
L3
Open - close - open - close
L4
Apartment block
L5
Apartment block 2 (more than 2" generates stop)
L6
Step-step 2 (less than 2" generates partial open)
L7
Hold-to-run
L8
Opening in "semiautomatic", closure in "hold-to-run""
L1
Speed 1 (30% - slow)
L2
Speed 2 (44%)
L3
Speed 3 (58%)
L4
Speed 4 (72%)
L5
Speed 5 (86%)
L6
Speed 6 (100% - fast)
L7
Open V4, close V2
L8
Open V6, close V4
L1
Door Open Indicator
L2
Active if door closed
L3
Active if door open
L4
Flashing light
L5
Electric block
L6
Electric lock
L7
Suction cup
L8
Maintenance indicator
L1
Force 1 (low)
L2
Force 2
L3
Force 3
L4
Force 4
L5
Force 5
L6
Force 6
L7
Force 7
L8
Force8 (high)
L1
Force 1 (low)
L2
Force 2
L3
Force 3
L4
Force 4
L5
Force 5
L6
Force 6
L7
Force 7
L8
Force8 (high)
Value
Description
Sets the pause time, i.e. the
time before automatic
closure. Applied only when
auto-matic closure function
is enabled
Sets the sequence of
commands associated with
the SS input or the 1st
radio command.
Sets the motor speed
during normal travel.
Selects the device
connected to the FLASH
output.
Sets the system for
controlling motor force, to
adapt it to the weight of the
door during the opening
manoeuvre.
Sets the system for
controlling motor force, to
adapt it to the weight of the
door during the closing
manoeuvre.