Impianto Elettrico; Instalación Eléctrica - Rotary SPMA32 Mode D'emploi

Table des Matières

Publicité

11. ELEKTROANLAGE
Netzanschluss nur durch Elektrofachkräfte
11. ELECTRICAL INSTALLATION
Power installations must be made by the user

11. IMPIANTO ELETTRICO

Installazione da eseguire dall'utilizzatore
SPMA32
TERMINAL
TR
COMMAND TRANSFORMER 50 VA 0-230-400/0-24
STM1/2 1/2 MOTOR HEAT PROBE
PS
UP BUTTON
PD
DOWN BUTTON
M1/2
1/2 POST MOTOR
KS
UP CONTACTOR
KM1/2
1/2 MOTOR COMMAND CONTACTOR
KD
DOWN
CONTACTOR
IG
MAIN SWITCH
FU3
SECONDARY PROTECTION FUSE TR.5X20 3.15A 250V RAPID FUSIBILE PROTEZIONE SECONDARIO TR.5X20 3.15A 250V
FU2
PRIMARY PROTECTION FUSE TR.10.3X38 1A 500V gl
RAPID
FU1
TRIPLET OF MOTOR LINE FUSES
25A 400V aM (DELAYED)
FCS
RISE LIMIT SWITCH
FCD1/2 1/2 CARRIAGE DESCENT LIMIT SWITCH
FC2
LIMIT SWITCH TO BLOCK CARRIAGE 2 TO HIGHER
THAN CARRIAGE 1
FC1
LIMIT SWITCH TO BLOCK CARRIAGE 1 HIGHER THAN
CARRIAGE 2
RIFER. DENOMINATIONS
11. INSTALLATION ÈLECTRIQUE
L'installation doit être effectée par l'usager
11. ESQUEMA ELECTRICO
La instalación tiene que efectuarla el utilizador
MORSETTO
TRASFORMATORE COMANDI 50 VA 0-230-400/0-24
SONDA TERMICA MOTORE 1/2
PULSANTE DI SALITA
PULSANTE DI DISCESA
MOTORE COLONNA 1/2
CONTATTORE DI SALITA
CONTATTORE COMANDO MOTORE 1/2
CONTATTORE DI DISCESA
INTERRUTTORE GENERALE
RAPIDO
FUSIBILE PROTEZIONE PRIMARIO TR.10.3X38 1A 500V gl
RAPIDO
TERNA FUSIBILI PROTEZIONE LINEA MOTORI
25A 400V aM (RITARDATI)
FINECORSA DI SALITA
FINECORSA DI DISCESA CARRELLO 1/2
FINECORSA CARRELLO 2 PIÙ ALTO DEL CARRELLO 1
FINECORSA CARRELLO 1 PIÙ ALTO DEL CARRELLO 2
NOMENCLATURA
11
49