10. LU-2220N-7 NEEDLE THREAD CLAMP FUNCTION
For the Needle thread clamp function, there are the functions below.
Function No. 156
0 : When the Needle thread clamp switch is turned ON, the function becomes valid.
Needle thread
1 : Needle thread clamp function becomes invalid.
clamp function
2 : Regardless of turning ON/OFF of the Needle thread clamp switch, the function
[How to make the setting]
1) Refer to "1. Setting of the mounted head, 1) How to enter into the function setting mode", and enter into
the function setting mode.
switch ❸ or
2) Press
switch ❺ or
3) Press
switch ❸ or
4) Press
becomes valid.
❶
❷
❸
❹
switch ❹ to call out function setting No.156.
switch ❻ and select the function.
switch ❹ and return to the function setting mode.
Function
❺
❻
❼