BE 14 Electric Boiler
Table of Contents
Symbols used ........................................................................ 5
Installation instructions
Site selection and installation .......................................... 5
Water connection ............................................................... 6
Function test ....................................................................... 7
Warnings ............................................................................. 7
Symbols used
The unit must only be installed and repaired by an
expert.
Symbol indicates a possible hazard.
Note containing information and tips.
Installation instructions
24
20
17
5
1
6
2
14
16
Fig. A
24
20
17
5
1
6
2
7
14
8
16
Fig. B
The unit must only be installed and repaired by an ex-
pert. Read the installation instructions carefully before com-
mencing the work, and then comply with them!
The year when the equipment was first taken into oper-
ation must be indicated with a cross on the type plate.
Site selection and installation
Select an installation site (not in installation compartment
behind heater) that makes the hot water pipes as short as
possible. The boiler must be easily accessible at all times for
service work and be easy to remove and install.
Securely screw boiler to suitable surface (laminated wood
panel, laminated wooden batten or metal surface) on floor of
vehicle with B 5.5 x 70 screws and washers (1). Always use
the insertion sleeves (2) that are preinstalled in the factory to
reinforce the insulating jacket.
3
9
7
8
4
9
5