Control Panel Installation; 230 V Electrical Connection; Function Test; Warnings - Truma BE 14 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8

Control panel installation

When using vehicle-specific or manufacturer-specific
control panels, the electrical connection must be made
according to the Truma interface description. Any modi-
fications to the associated Truma parts will invalidate the
warranty and preclude any liability claims The installer (man-
ufacturer) is responsible for providing the user with operating
instructions and the information that is printed on the control
panels.
When choosing a location, please note that the control
panel (20) must not be subjected to direct heat radiation.
Length of connector cable 2.5 m.
If the control panel cannot be flush-mounted, Truma can
provide an on-surface frame (18 – part no. 40000-52600)
as an accessory if required.
Drill hole with diameter of 55 mm. Guide through the
cable (19) towards the rear and secure the control panel (20)
with 4 screws (21). Then clip on the cover frame (22) and
route cable (19) to boiler.
5 5
19
Ø
18
Fig. 4
Truma supplies side parts (23) as accessories to improve
the appearance of the cover frame (22). Please contact your
dealer.

230 V electrical connection

The electrical connection must always be made by
an expert (in accordance with VDE 0100, part 721 or
IEC 60364-7-721 in Germany). The instructions shown here do
not constitute a request to non-experts to make the electrical
connection, but serve as additional information for an expert
who is employed to do the work!
The power connection is made using a 3 x 1.5 mm² cable (e.g.
hose line H05VV-F) to a distribution socket (fig. A + B: 24 –
not included in scope of delivery). A connector cable with a
plug is not permitted.
It is imperative that connection is carried out with care while
observing the correct colours!
An insulating device for providing all-pole insulation from
the mains with contact clearance of at least 3.5 mm must be
provided by the customer for carrying out maintenance and
repair work.
Fig A + B
Attach distribution socket (24) to floor or wall of vehicle near
device (cable length 110 cm).
Connect control panel cable, 230 V supply cable and heating
element cable in accordance with connection plan
m
m
21
20
23
22
23
Fig. 5
1 = Control panel cable
2 = Supply cable 3 x 1.5 mm²
3 = Heating element cable
4 = brown
5 = green
6 = blue
7 = yellow
8 = white
9 = yellow/green
All cables must be secured with clamps.

Function test

The water connections must be checked for leaks and all
functions must be tested as described in the operating
instructions after installation.
Then it must be ensured that all of the water (14 litres) drains
when the system is emptied.
There shall be no claims under guarantee for damage
caused by frost!

Warnings

The yellow sticker containing warning information that is
enclosed with the appliance must be affixed by the installer
or vehicle owner in a location in the vehicle where it is clear-
ly visible to all users (e.g. on the wardrobe door)! Missing
stickers can be requested from Truma.
Right reserved to make technical changes.
7

Publicité

Table des Matières
loading

Table des Matières