Preparation
Observe the instructions in the section entitled „Safety".
The device must be in an upright position.
into the tank.
1. Pull up the red button on the safety valve [12] until all excess pressure is released from
the tank. (Fig. 4).
2. Press the pump handle [13] down and turn it counterclockwise.
3. Unscrew the pump [2] from the tank [1]. (Fig. 6).
+
4. Add the spraying liquid to the tank [1] (Fig. 7).
5. Screw the pump [2] into the tank [1]. (Fig. 9).
6. Press the pump handle [13] down and turn it clockwise.
+
8. Press the pump handle [13] down and turn it counterclockwise.
Ensure that the initial pressure is not higher than 15 bar (218 psi).
7. When the required pressure has built up
hose [17].
(Fig. 5).
(Fig. 10).
in the tank [1] (Fig. 11).
(Fig. 5).
(88 psi)
16
, remove the compressed-air
(Fig. 12).