Preparation

Observe the instructions in the section entitled „Safety".
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
1. Pull up the red button on the safety valve [12] until all excess pressure is released from
the tank. (Fig. 4).
2. Raise the locking cap [10], tilt the cover [11], screw it in a clockwise direction and take
out of the filling opening. (Fig. 5a + 5b)
3. Add the spraying liquid to the tank [1]. (Fig. 6)
+
We recommend you mix the spraying liquid in the device or premix it in an external tank:
Fill to 1/3 with water, pour in the spraying agent, and then add more water until full.
4. Check the filling height on the scale stamped on the tank [13]. (Fig. 6)
5. Insert the tilted cover [11] into the filling opening and rotate the cover in a counter-clock-
wise direction. (Fig. 7a)
6. Tighten the cover in the tank upwards onto the filling opening and fold down the locking
cap [10]. (Fig. 7b)
► Filling opening is sealed. (Fig. 7b)
7. Press the pump handle [14] down and turn it counter-clockwise direction.
► The pump handle is unlocked. (Fig. 8)
8. Create the desired pressure (→ Table 2) in the tank (Fig. 9a).
+
The maximum pressure should not exceed 6 bar (red line on the pressure gauge
[15], Fig. 9b). If the maximum pressure is exceeded, the safety valve will engage and
release the excess pressure.
9. Press the pump handle [14] down and turn it clockwise.
► The pump handle is locked in place. (Fig. 10)
Spraying
Observe the instructions in the section entitled "Safety".
Operate the device only while it is vertical or suspended upright and nearly vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
1. Suspend the device from your shoulder. (Fig. 13)
+
To prevent dripping, hold the spray wand up when first spraying and activate the shut-
off valve until no more liquid mixed with air is emerging from the nozzle.
2. If required, reset the wheel lock [40] and activate the shut-off valve [9]. (Fig. 15)
► Spraying may now begin.