SECTION 3 − SPECIFICATIONS AND INSTALLATION
3-1. Specifications
Input Power
Rated Welding
Single-Phase
Output
AC
115 Volts Stick
70A @ 22.8 Volts DC,
And TIG
100% Duty Cycle
15A
70A @ 22.8 Volts DC,
100% Duty Cycle
115 Volts Stick
115 Volts Stick
20A
100A @ 24.0 Volts DC,
35% Duty Cycle
100A @ 14.0 Volts DC,
100% Duty Cycle
115 Volts TIG
115 Volts TIG
20A
150A @ 16.0 Volts DC,
30% Duty Cycle
100A @ 24 Volts DC,
100% Duty Cycle
230 Volts Stick
230 Volts Stick
150A @ 26.0 Volts DC,
30% Duty Cycle
100A @ 14.0 Volts DC,
100% Duty Cycle
230 Volts TIG
230 Volts TIG
150A @ 16.0 Volts DC,
30% Duty Cycle
*Sense Voltage For Stick And TIG Lift Arct
3-2. Duty Cycle And Overheating
250
200
STICK
(230V)
150
STICK
(115V 20A)
100
50
TIG/STICK
(115V 15A)
0
10
Amperes In-
Welding
Max
put At Rated
Amperage
OCV
Load Output,
Range
DC
50/60Hz,
Single-Phase
90V
20 − 100A
17.4
*12-16
17.4
90V
90V
20 − 100A
20 − 100A
*12-16
26.4
18.4
90V
90V
5 − 150A
5 − 150A
*12-16
28.0
13.1
90V
90V
20 − 150A
20 − 150A
*12-16
21.6
8.3
90V
90V
5 − 150A
5 − 150A
*12-16
14.2
TIG (115V 20A
& 230V)
50
% DUTY CYCLE
KVA @
Duty
KW
Dimensions
Cycle
2.0
1.9
2.0
1.9
3.0
3.0
2.1
2.1
H: 9 in (229 mm)
H: 9 in (229 mm)
W: 5.5 in (140 mm)
3.4
3.1
L: 13.25 in (337 mm)
L: 13.25 in (337 mm)
3.0
2.8
4.9
4.7
2.0
1.9
3.2
3.1
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, the
Overtemperature Light comes On,
and the cooling fan runs. Wait fif-
teen minutes for unit to cool. Re-
duce amperage or duty cycle be-
fore starting to weld again.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
100
Weight
13.7 lb
13.7 lb
(6.2 kg)
208 608-D
OM-2242 Page 7