SECTION 3 − SPECIFICATIONS AND INSTALLATION
3-1. Specifications
Input Power
Rated Welding
Single-Phase
Output
AC
70A @ 22.8 Volts DC,
100% Duty Cycle
115 Volts Stick
115 Volts Stick
100A @ 24.0 Volts DC,
35% Duty Cycle
100A @ 24 Volts DC,
100% Duty Cycle
230 Volts Stick
230 Volts Stick
150A @ 26.0 Volts DC,
30% Duty Cycle
* Sense Voltage For Stick

3-2. Duty Cycle And Overheating

250
200
150
100

3-3. Volt-Ampere Curves

100
80
60
40
20
0
0
OM-2246 Page 8
Welding
Max
Amperage
OCV
Range
DC
90V
90V
20 − 100A
20 − 100A
*12-16
90V
90V
20 − 150A
20 − 150A
*12-16
Stick (230V)
Stick (115V)
50
0
10
% Duty Cycle
230V Stick Max
115/230V Stick Min
50
100
Amperes
Amperes In-
put At Rated
KVA @
Duty
Load Output,
KW
50/60Hz,
Cycle
Single-Phase
17.4
2.0
1.9
26.4
3.0
3.0
13.1
3.0
2.8
21.6
4.9
4.7
100
115V Stick Max
150
200
Dimensions
Weight
H: 9 in (229 mm)
13.2 lb
(6.0 kg)
(6.0 kg)
W: 5.5 in (140 mm)
W: 5.5 in (140 mm)
L: 13.25 in (337 mm)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, the
Overtemperature Light comes On,
and the cooling fan runs. Wait fif-
teen minutes for unit to cool. Re-
duce amperage or duty cycle be-
fore starting to weld again.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
208 733-C
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of welding
power source. Curves of other set-
tings fall between curves shown.
208 732-B