6. OPERATION

6.1 Setting and viewing the set point

(desired water temperature)
In OFF mode and in ON mode
Press the
or
Press the
or
The settings are made with a precision of 0.5°C.
The settings are automatically saved after 5 sec. if no button is pressed.
It is recommended that the temperature never go above 32°C to prevent
alteration of the liners.

6.2 Water flow setting

While the heat pump is running and the water inlet and outlet valves are open,
adjust the bypass valve (see diagram below)
to obtain a difference of 2°C between the water inflow and outflow
temperatures.
• Opening the bypass valve results in a lower flow in the heat pump's
exchanger, leading to an increase in the inflow/outflow temperature
difference.
• Closing the bypass valve results in a higher flow in the heat pump's
exchanger, leading to a decrease in the inflow/outflow temperature
difference.
You can check the setting by viewing the inflow/
outflow temperatures (1-2) directly in the "EyesPool
Inverter Connect" app (see page 14).
button once to view the set point.
button twice to choose your desired set point.
1
2