4. INSTALLATION AND CONNECTION (continued)
4.3 Hydraulic connection
The heat pump comes with two 32 mm/38 mm fittings.
►
Wrap the threads of the fittings 15 to 20 times around with teflon.
►
Screw in the two fittings as indicated in the figure below.
►
Connect the bypass kit (1) and the pipes, following the direction of
circulation indicated in the figure.
See also the diagram on page 8.
►
Once the device has water running through it, verify that the connection is
watertight. Add teflon if there is a leak.
Water outlet
Water inlet
Fittings
Bypass kit
towards (4) and the pool
from the pool
and the pump (2-3)