Inductors Et Adaptators - GYS POWERDUCTION 110LG Manuel D'utilisation

Masquer les pouces Voir aussi pour POWERDUCTION 110LG:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Translation of the original instructions
1. Press the button (10), the pump stops and the LED (9) switches on.
2. Place the lance on its supports and put the cable on the ground (to prevent loss of cooling
liquid).
3. Unscrew the inductor by hand.
4. Depending on the choice of the new inductor: unscrew the adapter with the supplied
wrench and then screw the appropriate adapter back on (max. 7 N.m) or keep the adapter
already in place.
5. Screw the new inductor back on.
6. Press the button again (10).
The pump activates. For 5 seconds, the LEDs display a wait pattern.
If the flow is correct, the machine emits a double «BEEP» and the product is ready to operate.
Otherwise a fault is displayed (refer to the fault code table).

Inductors et Adaptators

The Powerduction 110LG/160LG are delivered as standard with the 32L adapter and the L90 inductor.
The other accessories are optional, they allow to extend the heating possibilities to multiple applications.
Adaptators
Inductors
«PURGE» MODE
This mode is only available if the heat is not activated (green switch is off).
1. Push the button (10), the pump stops and the LED (9) lights up.
2. Position the torch on its support and place the cable on the floor (to avoid liquid spillage).
3. Unscrew the accessory by hand.
4. Push and hold the heat authorisation button (2) for 3 seconds until it lights up.
5. Place the torch button above a bucket with a capacity of 10 l minimum.
6. Push the torch button (11). The pump activates until the debit falls under 2 l/minute or for 2 minutes. The machine
displays the debit in decilitre per minute. To interrupt the pump during the cycle, push any button.
7. To empty the cooling circuit, use a blower to blow air (30PSI) at the end of the torch until you can hear the air
flowing or projections of liquid coming out of the tank.
8. To remove the remaining liquid from the bottom of the tank
110 LG: use a vacuum pump or tilt the product to the front.
160LG: unscrew the cap under the Powerduction with a wrench (6 pan of 8).
Once the tank is completely empty, screw the cap back on.
30
POWERDUCTION 110LG / 160LG
Adaptator 32L
Ref. 064515
Inductor L90
Ref. 059788
Inductor L70
Ref. 059771
Inductor L180
Ref. 059795
Inductor L180
SPIRAL
Ref. 065000
Adaptator 32S
Ref. 064508
Inductor S90
Ref. 058927
Inductor S180
Ref. 059269
Inductor S180/B1
Ref. 064881
EN
3
4
2
Inductor S70
Ref. 061569
Inductor S20/B1
Ref. 064874
Inductor S180/B2
Ref. 064928

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Powerduction 160lg

Table des Matières