Translation of the original instructions
To set and then activate the heating:
1.  Adjust the regulation set point: press the adjustment buttons (4).
The regulation set point varies from 80°C to 350°C (default value at 250°C) in 10°C steps.
The setpoint is displayed for 1 second.
2.  Set the heating power set point (%): hold down the "inductor change" button (10) and press the control buttons
(4). The heating power setpoint varies from 10% to 100% (default value is 50%). The power is updated on the bar
graph.
3.  Activate heating: Close the user contact (Start 9-10). As long as it remains closed, the heating is active.
The minimum power indicator light (3) flashes at 10 Hz to indicate that the power is active.
It is possible to reset the heater when it is active. In this case, it is not necessary to perform step 3 since the
user contact is already closed. The heating in progress adapts to his new instructions.
When using the outdoor temperature interface, disconnect the pneumatic pedal from the product and connect
it to the interface.
PLC mode
It is possible to order the product via a PLC (see pinning).
Use the front panel connector or through the external interface.
To enter the "outdoor temperature control" mode:
1. Switch on the product.
2. Wait until the end of the start-up phase for 5 s.
3. Close the Start contact.
4. Wait for the OK/Secure output to close.
5. Release the Start contact after detecting the OK/Secure.
6. Check that the OK/Secure output remains closed.
The product enters the "external regulation mode" and generates a melody.
The heating enable button (2) and the lance button LED (11) flash once per second as long as the mode is activated.
To set the temperature set point and heating power, perform the same operation as in manual mode.
To activate the heating
1. Close the Start contact. The product will heat up until it reaches and regulates the set temperature.
If the product detects a fault, then the OK/Secure output opens and the heating stops.
To acknowledge the fault, open the Start contact and press the heating enable button (2).
The product returns to the "regulation" mode.
Start chronogram by PLC
Gâchette
Mecha
trigger
méca
relais
external
extérieur
relay
mode
drive mode
asservissement
POWERDUCTION 110LG / 160LG
500ms
500ms
500ms
EN
33