POWERDUCTION 110LG / 160LG
Dangerosity of the gas fumes
• Keep the head away from the fumes, do not inhale.
• If working inside, ventilate the area or use a fume extractor to
evacuate the gases and fumes.
• Induction heating of certain materials such as adhesives and
flux can generate fumes and gases. Breathing these fumes and
gases can be dangerous for your health. For example, heating
urethane generates a gas : hydrogen cyanide, potentially mor-
tal for hu-mans.
• If the ventilation is insufficent, use an approved respiratory unit.
• Read the safety data sheets (MSDS) and the manufacturer's
ins-tructions for adhesvies, flux, metals, consumables, coatings,
clea-ning agents, corrosives, and paint strippers.
• Do not use the heater on parts being degreased or sprayed.The
heat might react with fumes and generate highly toxic gases.
• Work in a confined area only if it's well ventilated, or use an
ap-proved repiratory/filtration unit. Make sure that a qualified
per-son is around to watch over you. The fumes and gases re-
leased while heating can replace oxygen or air, causing acci-
dents or death. Check the quality of the air you're breathing
• Do not overheat metals, such as galvanised steel, covered with
lead or cadmium, unless the coating is removed from the sur-
face before it's heated, that the area is well ventilated, and if
needed, use an approved filtration/respiratory unit.. Foundry
pieces and all metals containing such elements may generates
toxic fumes if overheated.
• Check the MSDS for temperature related details.
Warning, electrical danger
Caution: Danger of optical radiation when the heated metal ele-
ments reach fusion.
Warning ! Major magnetic field. People wearing active or
passive implants must be informed.
No further protectective steps are required when the machine is
used on its own. Further restrictions and/or protective measures
may be necessary in other cases. After maintenance, the magne-
tic field levels must be checked be-fore the machine is used
again. When switched on, never put the inductor near the head
or vital organs.
After maintenance, the magnetic field levels must be checked be-
fore the machine is used again.
When switched on, never put the inductor near the head or vital
organs.
People wearing pacemakers are advised to not come close to
the machine. Risk of disruption of pacemaker operations when
close to the machine.
Consult a doctor before getting close to induction heaters.