Type of use / number of users / distances between the anchor points for
In addition, always follow the user instructions of the respective products!
Combining different products is possible.
After prior agreement with the manufacturer, the installation of the system can also be carried out directly on steel structures
and concrete components with sufficient load-bearing capacity.
IMPORTANT: If the distance between the anchor device and the falling edge is below 2.5 m, the distance between the anchor
points must be reduced in order to prevent the deflection of the stainless steel rope over the falling edge in case of a fall of a
secured person!
If you have any questions, please contact the manufacturer.
*)
When using the system in Germany, the information provided in the national technical approval Z-14.9-789 must be observed.
This generally limits the permissible spacing between each anchor point to a max. of 10 m.
In special cases outside of Germany and after consultation with the manufacturer, the max. distance between the anchor points
can be increased from 7.50 m to max. 10 m or from max. 10 m to max. 15 m.