Dip-Switch Only For T3S - Aprimatic T3S Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Dead man: this operating mode requires the physical presence of a person. The input of
terminal 12 assumes the "close" input function. To open, press the start push-button and
hold it down (opening input). When the push-button is released, the movement stops. To
close, press the close push-button and hold it down; if the photocells are obscured, the
device blocks movement: in this case, the operator must release the push-buttons and
press either open or close. This is also the case if the two push-buttons are pressed at
the same time.
DIP-SWITCH 3: selection of input 12. This DIP-SWITCH is used to select the function of input
12 (terminal board K2) as an ADDITIONAL OPENING SAFETY DEVICE or as CLOSE.
DIP-SWITCH 4: pre-flashing selection. This DIP-SWITCH is used to enable or disable pre-
flashing. It can be selected both during opening and closing. If the function is enabled,
before the automation starts opening or closing, the warning light and the flasher will be
enabled for 3 seconds before the it starts.
DIP-SWITCH 5: reverse stroke. This DIP-SWITCH is used to enable or disable the reverse
stroke at the end of the closing cycle, a procedure which "discharges" the automation of any
voltage which has accumulated during stopping against the mechanical limit switch. Do not
use with the Area barrier, AT64, AT62 and AT60. Switch to the OFF position.
DIP-SWITCH 6: 1 or 2 motor selection. Makes it possible to optimise the performance of the
anti-crush and slowdown controls with an operator that has 1 or 2 motors.
3.3.1

DIP-SWITCH only for T3S

DIP-SWITCHES 7 and 8: Use these two dip-switches to set the operating mode of the
receiver output channels 3 and 4 as follows:
Pulse mode (S7 and S8 OFF): for each transmitter
S7
S8
button enabling
command given, the output is enabled for a second.
1 s
OFF OFF
output
Step mode (S7 ON - S8 OFF): for each transmitter
command given, the output changes state (ON ®
button enabling
OFF and OFF ® ON).
ON OFF
Continuous mode (S7 OFF - S8 ON): the output remains
output
active as long as the transmitter command persists.
button enabling
S7 and S8 ON: This configuration is not used. This
OFF ON
output
setting disables output channels 3 and 4.
NOTE - The output channels 1 and 2 operate with a pulsed output which has a duration
of 1 second.
ENGLISH
DIP-SWITCH 9 and 10: The receivers may be used with 2-, 4- or 14-button remote controls.
For a 14-button remote control, use the switches SW9 and SW10 to set the row of
buttons that the receiver will respond to; settings are as follows:
SW9
O F F
ON
SW10
O F F
O F F
INFORMATION:
The receiver may also receive commands from 2- and 4-button remote
controls (TR2 and TR4); in these cases the switches SW9 and SW10 must be set to OFF
(first configuration above).
INFORMATION:
The receiver microprocessor reads the position of the switches SW7 to
SW10 at start-up: If there has been a variation in the configuration of the switches SW7 to
SW10, to implement these changes, you must turn the device OFF and back ON again.
Jumpers JP5 to JP8: Use the jumpers JP5 to JP8, to set which receiver output channel and,
therefore, which remote control button, will enable the output signal.
This setting is made by closing just one of the jumpers present as follows:
JP5 - Channel 1 - Button 1 / JP6 - Channel 2 - Button 2
Ch4
JP8
JP7 - Channel 3 - Button 3 / JP8 - Channel 4 - Button 4
Ch3
JP7
OUT RX
WARNING: Only close one jumper. Closing more than one jumper
Ch2
JP6
may damage the device.
Ch1
JP5
O F F
ON
ON
ON
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T3e

Table des Matières