Preparation - Aprimatic T4-PROFESSIONALE Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Equipment supplied with a mains power supply of 230 VAC 50Hz, dedicated to piloting and control
of swing gates driven by electro-mechanical operators supplied with power at 24 VDC. Stand-by
consumption: 15 W. Maximum power of the operators/motors: 520 Watt.
All functioning mode selection, parameter setting and function setting is carried out using a device
known as the PROGRAMMER, supplied exclusively to qualified APRIMATIC installers.
1.1 BLOCK DIAGRAM OF EQUIPMENT
J1
Signal terminal board
J2
Power terminal board
J3
Radio receiver plug-in connector
J4
Connector for additional cards
CB
Battery charger connection terminal
board
M1
Motor 1 connection terminals
M2
Motor 2 connection terminals
20VAC Secondary transformer terminal
F1
Mains 3.15A fuse
F2
20 VAC low voltage 16A fuse
F3
Motor 1 8A fuse
F4
Motor 2 8A fuse
F5
Electric lock 2A fuse
The connector for the programmer is on the CPU card.
CAUTION - The product may only be installed by the qualified technical personnel of the
assistance and/or assembly service.
CAUTION - The electrical system must comply with current standards in the country where the
unit is installed.
CAUTION - Always disconnect the power supply before opening the container.

2.1 PREPARATION

Before assembling the equipment, prepare the tools required for wall-mounting and for the electrical
connections. The following are also required:
1.
6 mm diameter expansions plugs
2.
Skintop type PG16 cable clamps
3.
a multipole switch with minimum contact opening of 3 mm
4.
an emergency push-button
5.
approved cables for external use with cross-section of 0.75 minimum and 2.5 mm²
F6
Logic and accessories 2A fuse
ST1
Start input LED
ST2
Pedestrian Start/Close input LED
STOP
Stop input LED
FOTO
Standard photocell input LED
F.IN
Additional photocell input LED
F.C.M1 Motor 1 limit switch input LED
F.C.M2 Motor 2 limit switch input LED
POWER 24 VDC power supply present LED
K1
Motor 1 ON/OFF relay
K2
Motor 2 ON/OFF relay
K3
Motor 1 direction relay
K4
Motor 2 direction relay
K5
Electric lock relay
-
M2
+
-
M1
+
-
+
-
+
J2
N
18
Ph
17
N
16
Ph
15
Opening delay
Closing delay
From the battery charger circuit
20 VAC – From the secondary transformer
To the primary transformer
230 V - 50 Hz
T4Prof.EPS

Publicité

Table des Matières
loading

Table des Matières