Electrical Connections - Aprimatic T4-PROFESSIONALE Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.2 ASSEMBLY
You do not need to drill holes to fit the equipment.
1.
Assemble the equipment at a height of at least 30 cm, using the holes in the plastic container.
2.
Insert the connection cable, using the pre-marked holes on the bottom of the container and
the cable clamp indicated.
3.
Install the multipole switch upstream of the equipment.
4.
Install an emergency push-button in a position which allows you to see the operator system
and which ensures that the switch completely cuts off the power supply to the operator.
5.
Use the 2.5 mm² minimum cross-section cable to connect the mains power supply to the
motor; for connections longer than 6 m, use cable with a cross-section of 4 mm². Use the
0.75 mm² cross-section cable for the other 24 VDC devices.

2.3 ELECTRICAL CONNECTIONS

CAUTION - Before making the connections, turn OFF the mains power supply.
CAUTION - Do NOT use intercom or telephone cable.
Make the electrical connections as indicated in the diagram.
NOTE - As envisaged by current standards, separately strap the connection cable for the
controls (terminals from 1 to 14) and the power cable (terminal boards M1 and M2).
After making the connections as indicated and carefully checking the electrical connections, turn
the mains power supply ON and check that the system is operating correctly as specified below.
3.1 FUNCTIONING TESTS
After making the connections, check the operator system: when you press the start push-button,
the gate must open. If the gate closes, invert the motor connections.
3.2 ADJUSTMENTS
Use the programmer to adjust the operator work time and mode.
CAUTION - The pins on the connector must be plugged in correctly; if the connector is difficult to
insert, check that it is the right way round.
NOTE - The number indicated in front of the description for each parameter is the number
which indicates the function in operation. The values are shown on the PROGRAMMER
display (2 left-side digits).
The square brackets contain the setting range of the PROGRAMMER (2 right-side digits).
10 – WING OPENING DELAY (0 – 20 s) [Range: 0 – 20]
Delays opening of one wing compared to the other wing controlled by the same operator.
11 – WING CLOSING DELAY (0 – 20 s) [Range: 0 - 20]
Delays closing of one wing compared to the other wing controlled by the same operator.
J1
14
13
+
12
-
11
-
10
+
9
-
8
+
7
6
Shared inputs
5
Opening safety device photocell
4
Photocell
3
Stop
2
Pedestrian start/Close
1
Start
N.B. All the N.C. safety contacts (Stop, photocells and motor limit switches) must be jumpered
if they are not used.
CAUTION!
Strap the low voltage cables together near terminal board J1. Strap the power cables together
near terminal board J2.
12 - APPROACH/SLOW-DOWN SPEED [Range: 0 – 20]
The gate slows down when it reaches the limit switch (during opening or closing). This prevents
violent knocking of the gates. Can only be enabled for operators with limit switches.
13 – PAUSE TIME (2 – 180 s) [Range: 1 – 90]
In the automatic operating mode, this function sets the pause time when the wings are open.
14 – WORK TIME (2 – 180 s) [Range: 1 – 90]
Adjusts the operator work time, which is especially useful for operators without limit switches.
15 – BRAKE ENABLING DELAY (0 – 2 s) [Range: 0 – 20]
This function is only used for sliding gates.
16 – ANTI-CRUSH DEVICE ADJUSTMENT [Range: 0 – 99]
Adjusts the sensitivity of the system which recognises obstacles, preventing movement of
the gates.
CAUTION - Set the parameter to 99 for the maximum operator thrust force.
17 – PARTIAL OPENING SPAN (0 – 32 s) [Range: 0 – 32]
This function is only used for sliding gates.
Motor 2 limit switch
Motor 1 limit switch
Electric lock
LED flashing unit
Max. 3 W warning light
Accessory power supply
T4PROFMO.EPS

Publicité

Table des Matières
loading