Minimum Pressure Tank And Supply Pipe Sizing - Franklin Electric SUBDRIVE UTILITY Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Minimum Pressure Tank and Supply Pipe Sizing

A VFD system needs only a small pressure tank to maintain constant pressure, although a larger
tank may be used. If adding a SubDrive Utility to a conventional system with an existing large tank,
refer to
"Tank Size and Bump Mode Adjustments" on page
The pressure tank pre-charge setting should be 70% of the targeted system pressure. To check the
tank's pre-charge, de-pressurize the water system by opening a tap with the drive off. Measure
with a pressure gauge at the inflation valve and make any necessary adjustments.
Refer to the following recommendations for best performance.
Submersible Pump Applications with Franklin Electric 2-Wire Motor
A minimum tank size of 20 gallons is recommended. This is to ensure water is available during the
minimum off time of the motor. If a smaller tank is used, the tank may empty if a large water
demand immediately follows a motor off cycle.
Submersible Pump Applications with PSC Motor
Pump Flow Rating
Less than 12 gpm (45.4 lpm)
12 gpm (45.4 lpm) and higher
Surface Pump Applications
Maximum Pump Flow
10 GPM
20 GPM
30 GPM
40 GPM
Minimum Supply Pipe Sizes
The minimum supply pipe inside diameter past the pressure sensor (transducer) should be
selected not to exceed a maximum velocity of 8 feet per second (2.4 m/s) based on the flow rate of
the system.
Maximum GPM (lpm)
11.0 (41.6)
19.6 (74.2)
30.6 (115.8)
44.1 (166.9)
78.3 (296.4)
176.3 (667.4)
28.
Minimum Tank Size
2 gallons (7.6 liters)
4 gallons (15.1 liters)
Minimum Tank Size
2 gallons (7.6 liters)
4 gallons (15.1 liters)
6
gallons (22.7 liters)
8 gallons (30.3 liters)
Minimum Pipe Diameter
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
INSTALLATION AND SETUP
Installation Process
15