Cleaning Recovery Tank; Cleaning Solution Filter - Nilfisk Advance SC5000 34D Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A - ENGLISH

CLEANING RECOVERY TANK

1
Drive the machine to the appointed disposal area.
2
Ensure that the machine is off and the SmartKey (39) is removed.
Pull the Recovery Tank Drain Hose (28) from its storage area.
3
4
Direct the hose to a designated "DISPOSAL SITE" and unscrew the cap (hold the end of the hose above the water level in the tank to avoid
sudden, uncontrolled flow of waste water). The Recovery Tank Drain Hose can be squeezed to regulate the flow.
5
Lift open the Recovery Tank Cover (24).
6
Rinse the recovery tank out thoroughly to remove any and all debris from the tank. To clean out the recovery tank leave the drain hose open
to a floor drain and spray the inside of the tank clean with a hose. A hose with a spray attachment can be used to spray out the recovery
tank but should not be directed onto the Vacuum Motor Filter Housing (26). Do not allow sprayed water to splash outside of tank or into the
vacuum motor inlet.
NOTE: The spray hose should not be used to clean the exterior of the machine near the operator control panel to prevent water ingress into
sensitive electronics.
7
Remove the Debris Catch Tray (27) from the recovery tank. Empty and rinse the debris catch tray then reinstall it.
8
Open the Vacuum Motor Filter Housing (26) and remove the filter. Remove any debris that has gathered inside the filter housing. Rinse the
filter then reinstall.
9
Check the condition of the recovery tank cover gasket and the area it seats against. They should be clean to create a good seal.
NOTE: The gasket allows the creation of a vacuum in the tank, which is necessary to vacuum up the recovery water.
10 Close the recovery tank cover. NOTE: The cover can be left open to air out the tank between uses.

CLEANING SOLUTION FILTER

1
Drive the machine to the appointed disposal area.
Ensure that the machine is off and the SmartKey (39) is
2
removed.
3
Close the Solution Shutoff Valve (37) by rotating the handle
90° so it's pointed at the right side of the machine (Figure 4-1
shows handle in the closed position).
Unscrew the solution filter cover (36). There will likely still be
4
some solution in the line that will spill out.
5
Clean the filter cover and screen.
6
Reinstall the screen and cover, ensure the gasket is in place.
7
Open the Solution Shutoff Valve (37).
A - 28
INSTRUCTIONS FOR USE
Advance SC5000 - 56091219
FIGURE 4-1
37
36
1/2021

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Advance sc5000 32cAdvance sc5000 36c561170015611700356117004

Table des Matières