DSA
TERMOROSA
15. SUMMER PERIOD OF INACTIVITY
WARNING: The system should be kept constantly full of water even in periods in which the use of the wood burning
stove/cooker is not required. During the winter, inactivity must be faced with the addition of antifreeze.
After cleaning the furnace, chimney and flue, eliminating the ash and any other residue completely, close all the doors
of the furnace and the relevant registers and disconnect the appliance from the chimney.
We advise cleaning the flue at least once a year; in the meantime check the condition of the gaskets, which if not
perfectly integral do not guarantee good operation of the appliance! In this case replace them.
Protect the cast iron parts, if the aesthetic aspect wants to be kept intact over time, with neutral Vaseline.
16. CONNECTING A CHIMNEY OR OPEN FURNACE TO THE FLUE
The smoke channel is the section of tube that connects the thermal product to the flue, in the connection these simple
but very important principles must be followed:
•
for no reason must the smoke channel be
used with a diameter lower than that of
the neck of the outlet with which the
thermal product is fitted;
•
each metre of horizontal route of the
smoke channel causes a small leak of
charge which should be compensated for
by raising the flue;
•
the horizontal section must never be
higher than 2 m (UNI 10683-2005);
•
each
bend
of
considerably reduces the draught of the
flue which must be compensated for by
raising it suitably;
•
the UNI 10683-2005 Regulation –Italy
requires that the bends or variations of
direction must in no case be greater than
2 including the emission into the flue.
Wanting to use the flue of a chimney or open
furnace, it will be necessary to close the hood
hermetically below the inlet point of the smoke
channel pos. A Picture 12.
If the flue is too large (e.g. cm 30x40 or 40x50) it
is necessary to duct it with a stainless steel tube
of at least 200 mm of diameter, pos. B taking care
to close the space between the tube itself and the
flue immediately below the chimney cap pos. C.
For any further clarification please contact your
local trusted dealer!
7097501 – EN
the
smoke
channel
C - Plugging
B
A – Hermetic closure
Inspection
hatch
Picture 12
33