3.4. HEAT DISCHARGE VALVE (OPTIONAL)

Solid fuel thermo products must be installed with safety devices determined by laws in vigour.
For this reason the thermo stove/cooker is equipped with a heat discharge coil.
The heat discharge coil must have one side connected to the water network (Picture 3 A) and the other to the
drainage network(C). When the safety temperature is reached, the heat discharge valve, the bulb of which is to be
connected to attachment B, enables the intake of cold water in the boiler coil, discharging the excess heat out of pipe
C towards a conveniently installed drain.
Cooling circuit upstream pressure must be at least 1,5 bar.
A
4.

FIRE SAFETY

When installing the wood burning stove/cooker the following safety measures must be observed:
a) In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing
components flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with
flammable structure (see Picture 4 A). All of the minimum safety distances are shown on the product data
plate and lower values must not be used.
b) in front of the door of the furnace, in the area of radiation of the same, there must be no object or material of
inflammable construction and sensitive to heat at a distance of less than 100 cm. This distance can be reduced
to 40 cm if a retro-ventilated and heat resistant protection is installed in front of the entire component to be
protected.
c) If the product is installed on a non totally refractory floor, one must foresee a fireproof background. The floors
made of inflammable material, such as moquette, parquet or cork etc., must be replaced by a layer of no-
inflammable material, for instance ceramic, stone, glass or steel etc. (dimensions according to regional law). In
case the replacement of the floor is not possible, the appliance shall be placed on a minimum 12 cm
thick slab made of stone or concrete. The platform must project at least 50cm in front and each side by at
least 20cm beyond the opening of the loading door (see Picture 4 B).
d) no flammable components (e.g. wall units) must be present above the product.
The wood burning stove/cooker must operate exclusively with the ash drawer inserted. The solid residues of
combustion (ash) must be gathered in a sealed fire resistant container. The wood burning stove/cooker must never be
24