Installation Of Perimeter Wire - Stiga Autoclip M3 Manuel D'utilisation

Masquer les pouces Voir aussi pour Autoclip M3:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
The perimeter wire can be buried or laid on the ground. If you have a wire
layer machine, it is better to bury the wire for greater protection.
EN
Otherwise, install the wire on the ground with the pegs provided as
described below.
Important
Start laying the perimeter wire from the area where
the charging station is installed, leaving a couple of
extra meters so that it can be cut down to size when
connecting to the power unit during the final phase.
Ground wire
Cut the grass as low as possible with a grass trimmer or brushcutter
along the entire path where the cable will be laid. This will make it
easier to lay the cable in contact with the ground and reduce the
risk of the robot damaging the insulation.
1. Position the wire in a clockwise direction along the entire path and
secure it with the pegs supplied, making sure there is a maximum
distance of around 100 cm (39.37 inches) between each peg. The
wire must be in contact with the ground to prevent it from being
damaged by the robot before the grass covers it.
-
When laying the perimeter wire, follow the installation
direction around the flowerbeds, i.e. a counter-clockwise
direction.
-
In curved sections, secure the wire so that it is not twisted,
but curves nicely (radius of 20 cm).
radius of 20 cm
Buried wire
1. Dig an even furrow in the ground (approximately 2-3 cm or 0.787-1.181 ").
2. Position the wire in a clockwise direction along the track at a depth of a couple of centimetres. Do not bury the wire deeper
than 5 cm, so as not to reduce the quality and intensity of the signal picked up by the robot.
3. During the laying of the wire, it may be necessary to secure it in some points with the pegs provided in order to hold it in place
when covering with the ground.
4. Cover all the wire with soil and make sure it remains taut in the ground.
User's manual

INSTALLATION OF PERIMETER WIRE

wire fastening pegs
perimeter wire
perimeter wire
Max.
5 cm (1,96 ")
> 70 cm (27,56 ")
16
35 cm
(13,78 ")
NO
0 cm (0,0 ")

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Autoclip m5