Joining of the perimeter wire
Use an original joint if another perimeter wire is needed to complete
the installation.
Insert each end of the wire in the joint, making sure the wires are
fully inserted so that the ends are visible on each side. Press the
button on the upper side all the way down using a pair of pliers.
Important
-
For a safe and secure electrical connection,
only use original joints.
-
Do not use insulating tape or other types of
joints that do not provide proper isolation
(lugs, terminals, etc.). After some time, soil
moisture causes oxidation and interruption
of the perimeter wire.
INSTALLATION OF THE CHARGING STATION AND POWER SUPPLY UNIT
Warning – Caution
Before carrying out any operations, disconnect the
robot from the mains power.
Position the power supply unit in an area that
cannot be reached by children. For example, at a
height above 160 cm (63 ").
Do not shorten or lengthen the cable getting to the
charging station, wrap as an 8 like form the excess
cord, as shown in the figure.
The perimeter wire used for the installation cannot
be less than 50m, contact the closest customer
service centre .
1. Remove the protection (L).
2. Position the charging station in the predefined area.
3. Insert the perimeter wire (M) along the guide in the charging station. Cut the excess perimeter wire to about 5cm above the
connectors.
4. Connect the station incoming wire to red terminal of the transmitter (T). Connect the station outcoming wire to the black
terminal.
The terminals are used only to connect the original perimeter wire.
protection (L)
perimeter wire (M)
1
3
5
connect to
the red terminal
transmitter (T)
connect to
the black terminal
17
2
4
6
current power supply unit (A)
transmitter (B)
H. min. 160 cm
(63.00 ")
EN
protection (L)
User's manual