1
1
2
2
Dismount the 4 flue diverters (2 on the right and 2 on the left) placed on the combustion chamber sides and scrape the internal walls with a spatula removing
any deposit.
Do not force the flue gas intake device
flaps with the ash vacuum hose.
Use a suitable ash vacuum to remove the internal deposits and then re-position the base and the ash drawer.
If necessary, scrape the internal walls of the combustion chamber using a small steel spatula and suck any deposit, once cleaning is completed.
For correct functioning, it is necessary to use a suction device to remove the sawdust deposit on the base of the tank at least every 15 days.
The pellet tank must be emptied at the end of every season.