Connection to the room thermostat

A clamp is installed on the rear of the stove (free contact), which is useful for connecting any room thermostat. In this way, connecting an external
thermostat with the function to close or open the contact depending on the heat request will be easier.

CLEANING AND MAINTENANCE

Precautions before cleaning

Before carrying out any cleaning or maintenance, make sure that:
The stove is off and has cooled down completely;
The ash is completely cold;
Before re-starting the stove, re-install all previously disassembled components.
During the cleaning operations, use the individual protection devices envisioned by the 89/391/EEC Directive.
The frequency for cleaning depends on the type and quality of the burned pellet.. Therefore, the schedule indicated below may vary.
Any problem to the stove caused by the lack of cleaning will not be covered by the warranty.

Routine cleaning

The stove requires periodical cleaning at least every 20 days of functioning or after 3-4 ignitions, to always guarantee efficiency and optimal functioning.
OPERATION PRINCIPLE
With open contact and reached temperature on "SET ROOM TEMP" set in stove:
1. The stove goes to functioning economy "ECONOMY" reducing work power to minimum if the temperature set
in "SET ROOM TEMP" has also been reached in the equipment's installation room.
2. At this point, if the following condition exists, the stove automatically switches off "FIRE STOP" (switch-off in
stand-by):
If temperature differential set on Pr43 (2°C default setting) or Room temperature > ( "SET ROOM TEMP" +
Pr43 ) is exceeded after a time set on Pr44 (2 minute default setting).
The stove will automatically reactivate if at least one of the following conditions occur:
If the contact of the room thermostat closes.
If it drops below temperature differential set on Pr43 (2°C default setting) or Room temperature < ( "SET
ROOM TEMP" – Pr43 ).
If the above-mentioned condition occurs when the stove is still carrying out the switch off cycle, it is required to
wait until it ends.
Pull front knob to clean the ventilated hot air tubulars above the combustion chamber.
Activate knob only with stove off and cold.
8