What Happens If; Circuit Board Parameters - klover DEA PLUS Manuel D'installation Et De Maintenance

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WHAT HAPPENS IF..

...the pellet does not ignite
With no ignition. The "NO IGNIT" alarm message appears.
Cancel the alarm and bring the stove to standard condition by pressing key 4 for a few seconds.
...the fire door is open or closed improperly
In case the door is open or closed improperly, the motor reducer cannot be powered electrically, not allowing the stove to switch on. If the fire door is
opened during the normal functioning, the stove burns all the pellet in the brazier, activating the "NO PELLET" alarm (sudden switch off).
...the flue is dirty, blocked or not manufactured correctly
In case the flue is dirty, blocked or not manufactured correctly, the motor reducer cannot be powered electrically not allowing the stove to switch on. If the
flue blocks during the normal operation, the stove burns all the pellet in the brazier, activating the "NO PELLET" alarm (sudden switch off).
...the pellet tank goes in over-temperature
The motor reducer is not electrically powered with pellet tank over-temperature as the thermostat intervenes in manual re-arm. If it happens with stove
working, the latter goes in "NO PELLET" alarm (sudden switch-off). Therefore the thermostat must be rearmed before switching on the stove.
...lack of power (black out)
Upon restore after power outage due to time less than Pr48, the stove immediately re-starts from operative state it had before power outage (recovering the
set work power).Upon restore after power outage due to time more than Pr48, the stove sets on "STOP FIRE" (stand-by) mode and carries out the entire
switch off cycle until its cooling. Once this phase is completed, the thermo stove can be normally switched on to proceed working at the set power.
Previous state
OFF
START
START
LOAD PELLET
WAITING FIRE
FIRE ON
FIRE ON
WORK (any phase)
WORK (any phase)
BRAZIER CLEANING
BRAZIER CLEANING
FINAL CLEANING
FINAL CLEANING
STOP FIRE

CIRCUIT BOARD PARAMETERS

THE PARAMETERS MEMORISED ON THE CIRCUIT BOARD ARE FUNDAMENTAL FOR THE CORRECT FUNCTIONING OF THE STOVE.
THE PARAMETERS GIVEN BELOW ARE ALREADY MEMORISED IN THE STOVE INSPECTION PHASE DIRECTLY IN THE FACTORY.
THESE PARAMETERS ARE THE RESULT OF CAREFUL TESTS WITH VARIOUS TYPES OF PELLETS AND MUST NOT BE CHANGED WITHOUT
THE AUTHORISATION OF KLOVER srl, SO AS NOT TO JEOPARDISE STOVE FUNCTIONING.
ALL RESPONSIBILITIES ARE DECLINED FOR DAMAGE CAUSED BY INCORRECT INTRODUCTION OF THE PARAMETERS.
Parameter
Menu level
M – 9 – 5 – 01
Pr38
Re-ignition block
M – 9 – 5 – 02
Pr39
Flue gas intake device switch-off time
M – 9 – 5 – 03
Pr40
Pre-load time in ignition
M – 9 – 5 – 04
Pr41
Stand-by time after pre-load
M – 9 – 5 – 05
Pr42
Intake device speed in pre-load phase
M – 9 – 5 – 06
ON/OFF temperature hysteresis "SET ROOM"
Pr43
Delay to economy switch-off (timer after
M – 9 – 5 – 07
Pr44
reaching "SET ROOM" + Pr43 )
M – 9 – 5 – 08
Pr45
Power change delay
M – 9 – 5 – 09
Pr46
Exchanger 1 motor speed in switch-off phase
M – 9 – 5 – 10
Pr47
Keypad block enabling
M – 9 – 5 – 11
Pr48
Automatic re-ignition after black-out
M – 9 – 5 – 12
Pr49
Room probe calibration
Black-out duration
State after power restore
Any
OFF
duration < Pr48
START
duration > Pr48
START
Any
BLACK OUT ALARM
Any
BLACK OUT ALARM
duration < Pr48
FIRE ON
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
duration < Pr48
WORK (any phase)
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
duration < Pr48
BRAZIER CLEANING
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
FINAL CLEANING and after cooling  OFF
duration < Pr48
FINAL CLEANING and after cooling  OFF
duration > Pr48
Any
STOP FIRE
"Various calibrations" (Menu M – 9 – 5)
Description
Display writing
Measurement
RE-IGNIT BLOCK
MIN-INT OFF
IGNIT PRE-LOAD
AFTERPRE STANDBY
EXHMOTOR PRELOAD
DELTA ON OFF AUTO
DELAY OFF AUTO
POWER CHANGE
AIR IN OFF
KEYS BLOCK EN
BLACK OUT IGNITION
ROOM-T OFF-SET
16
Value field
0 – 10
Minutes
0 – 20
Minutes
0 – 225
Seconds
0 – 255
Seconds
500 – 2800
Revs/min
0 – 15
°C
2 – 120
Minutes
0 – 60
Seconds
65 – 225
Volt
On – off
On – off
0 – 60
Seconds
- 9 – 9
°C
Database
5
10
95
170
2200
2
2
30
225
OFF
30
0

Publicité

Table des Matières
loading

Table des Matières