Parameter
Menu level
M – 9 – 7 – 01
Pr01
Ignition cycle maximum time
M – 9 – 7 – 02
Pr02
Start time
Time interval between the two brazier cleaning
M – 9 – 7 – 03
Pr03
operations
Screw feed motor reducer ON time in ignition
M – 9 – 7 – 04
Pr04
phase
Screw feed motor reducer ON time in start
M – 9 – 7 – 05
Pr05
phase
Screw feed motor reducer ON time in power 1
M – 9 – 7 – 06
Pr06
work phase
Screw feed motor reducer ON time in power 2
M – 9 – 7 – 07
Pr07
work phase
Screw feed motor reducer ON time in power 3
M – 9 – 7 – 08
Pr08
work phase
Screw feed motor reducer ON time in power 4
M – 9 – 7 – 09
Pr09
work phase
Screw feed motor reducer ON time in power 5
M – 9 – 7 – 10
Pr10
work phase
M – 9 – 7 – 11
Pr11
Alarm delay
M – 9 – 7 – 12
Pr12
Brazier cleaning duration
Flue gas minimum temperature to consider the
M – 9 – 7 – 13
Pr13
stove on
M – 9 – 7 – 14
Pr14
Flue gas maximum temperature
Flue gas temperature threshold for igniting the
M – 9 – 7 – 15
Pr15
exchangers
M – 9 – 7 – 16
Pr16
Flue gas intake device speed in ignition phase
M – 9 – 7 – 17
Pr17
Flue gas intake device speed in start phase
M – 9 – 7 – 18
Pr18
Flue gas intake speed in power 1 work phase
M – 9 – 7 – 19
Pr19
Flue gas intake speed in power 2 work phase
M – 9 – 7 – 20
Pr20
Flue gas intake speed in power 3 work phase
M – 9 – 7 – 21
Pr21
Flue gas intake speed in power 4 work phase
M – 9 – 7 – 22
Pr22
Flue gas intake speed in power 5 work phase
Exchanger 1 motor speed in power 1 work
M – 9 – 7 – 23
Pr23
phase
Exchanger 1 motor speed in power 2 work
M – 9 – 7 – 24
Pr24
phase
Exchanger 1 motor speed in power 3 work
M – 9 – 7 – 25
Pr25
phase
Exchanger 1 motor speed in power 4 work
M – 9 – 7 – 26
Pr26
phase
Exchanger 1 motor speed in power 5 work
M – 9 – 7 – 27
Pr27
phase
Flue gas intake device switch-off threshold (in
M – 9 – 7 – 28
Pr28
switch-off phase)
Flue gas intake device speed in brazier
M – 9 – 7 – 29
Pr29
cleaning phase
Screw feed motor reducer ON time in cleaning
M – 9 – 7 – 30
Pr30
phase
Flue gas intake device encoder enabling
M – 9 – 7 – 31
Pr31
(UNUSED)
M – 9 – 7 – 32
Pr32
Screw feed brake time
M – 9 – 7 – 33
Pr33
START phase time
M – 9 – 7 – 34
Pr34
PRE-HEATING phase time
M – 9 – 7 – 35
Pr35
Flue gas intake device speed in START phase
Flue gas intake device speed in PRE-
M – 9 – 7 – 36
Pr36
HEATING phase
Flue gas intake device speed in FLAME
M – 9 – 7 – 37
Pr37
STAND-BY phase
"Default settings" (Menu M – 9 – 7)
Description
IGNIT MINUTES
START MINUTES
BRAZIER CLEANING
IGNIT SCREW
START SCREW
POWER 1 SCREW
POWER 2 SCREW
POWER 3 SCREW
POWER 4 SCREW
POWER 5 SCREW
ALARMS DELAY
BRAZIER CLEANING
THRESHOL MINIMUM
THRESHOL MAXIMUM
THRESHOL BLOWER
IGNIT FL GASSPEED
START FL GASSPEED
P 1 FLUE GASSPEED
P 2 FLUE GASSPEED
P 3 FLUE GASSPEED
P 4 FLUE GASSPEED
P 5 FLUE GASSPEED
AIR 1 SPEED
AIR 2 SPEED
AIR 3 SPEED
AIR 4 SPEED
AIR 5 SPEED
THRESHOL OFF
EXHMOTOR CLEANING
SCREW CLEANING
ENCODER
BRAKE TIME
START TIME
PRE-HEAT TIME
START GASSPEED
PRE-HEAT GASSPEED
STAND-BY GASSPEED
17
Display writing
Measurement
Minutes
Minutes
Minutes
Seconds
Seconds
Seconds
Seconds
Seconds
Seconds
Seconds
Seconds
Seconds
°C
°C
°C
Revs/min
Revs/min
Revs/min
Revs/min
Revs/min
Revs/min
Revs/min
Volt
Volt
Volt
Volt
Volt
°C
Revs/min
Seconds
On – off
Seconds
Seconds
Seconds
Revs/min
Revs/min
Revs/min
Value field
Database
5 – 25
25
0 – 12
2
3 – 240
50
0.0 – 4.0
1,0
0.0 – 4.0
0,8
0.1 – 4.0
1,0
0.1 – 4.0
1,5
0.1 – 4.0
2,2
0.1 – 4.0
2,9
0.1 – 4.0
3,2
20 – 90
30
0 – 120
60
40 – 180
43
110 – 250
250
40 – 210
60
500 – 2800
2200
500 – 2800
2000
400 – 2800
1700
400 – 2800
1900
400 – 2800
2100
400 – 2800
2200
400 – 2800
2300
65 – 225
190
65 – 225
195
65 – 225
200
65 – 225
205
65 – 225
225
50 – 250
70
500 – 2800
2800
0.0 – 4.0
0,6
On – off
ON
0.0 – 0.5
0,2
0 – 60
30
0 – 255
0
500 – 2800
2800
500 – 2800
2800
500 – 2800
2200