3.3 Water connection

Connect the appliance using the water hose to an easily accessible aeration tap that can be closed quickly
if problems arise. The minimum water pressure may not be under 0,2 Bar (at 5L/min. flow pressure)
The appliance can only be connected to a cold water outlet.
3.3.1

Water treatment

You are emphatically advised to use a water softener and/or a water filter if the water contains too much chlorine
or is too hard (>8°dH). This enhances the quality of the drink and precludes having to descale the appliance too
often.
3.4

Water drainage

Connect the overflow connection to the open connection with a drain (syphon) in such a way that the excess
water can be drained in case of a malfunction or maintenance.
3.5

Electrical connection

WARNING
Supply voltages and frequencies can differ between countries. Check if the appliance
is suitable for connection to the local power mains. Check if the details on the type plate
correspond.
The earthed wall socket and the fused group with a main switch belong to the electrical installation. No heavy
machines that could cause variations in power when being switched on, can be connected to this group.
A machine with power current (three phase) is delivered from the factory without plug. At delivery, the machine
must be provided with an electrically suitable plug as advised and provided by the installer.
(fig. 3) In case of 3N~ 400V (5-core cable).
(fig. 4) In case of 3~ 230V (4-core cable).
(fig. 5) In case of 1N~ 230V (3-core cable).
The following points should be observed when wiring a new plug:
1.
The green/yellow-coloured wire ("EARTH") should be connected to the terminal which is either marked
with the letter "E", the "earth" symbol (
2.
The blue-coloured wire ("NEUTRAL") should be connected to the terminal which is either marked with the
letter "N" or coloured black.
3.
The brown-coloured wire ("PHASE") should be connected to the terminal which is either marked with the
letter "L1, L2 and L3" or coloured red.
fig. 3
fig. 4
ComBi line
), or coloured green or green/yellow.
Green/Yellow - Earth (E)
Blue
- Neutral (N)
Brown
- Live 1 (L1)
Black
- Live 2 (L2)
Black
- Live 3 (L3)
Green/Yellow - Earth (E)
Brown
- Live 1 (L1)
Black
- Live 2 (L2)
Black
- Live 3 (L3)
50
Green/Yellow - Earth (E)
Blue
- Neutral (N)
Brown
- Live 1 (L1)