Technical Data; Menu Functions - Burg Wächter TSE Set 5001 PINCODE Directives De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical data

Blocking times
After 3 × wrong code is entered 1 minute,
then always 3 minutes
Display
Adjustable to 12 languages
Power supply
4 × MIGNON LR6 AA ALKALINE
Optimum ambient
-15 °C / +40 °C / Up to 95 % rel. air humidity
conditions
(noncondensing)
Allowed temperature range: -20 °C / +50 °C
As a result of extreme temperature changes, the
display can react slowly or darken.
TSE Set 5002 FINGERSCAN
Using this ident medium, you can control the cylinder based on fingerscan.
In addition, the cylinder can be controlled by entering a 6-digit code.
Up to 24 fingers can be programmed using the keypad.
The users are set separately (USER XXX_FP). In case a code and/or E-Key
is to be assigned additionnally to a user, this needs to be set separately.
Attention! The finger scanner must not be cleaned with detergents.
Please use a slightly moist cloth for this purpose. Please make sure that
the finger scan sensor is not exposed to direct rain.
TSE 5002 FINGERSCAN functions (as standard)
– Total number of users: up to 48
of which number of fingerscans: up to 24
– To each code user (except administrator) also an E-Key can be assigned
– To each E-key user a code can be assigned
Optional locking media
– Radio controlled key TSE 5103 E-KEY
Time functions
– User timer (up to 24 different time windows) *
– Permanent timer (up to 16 different time windows) *
* (only together with an appropriate TSE software)
* Presumably as from december 2009 it will be possible to
programme a fingerscan considering also the time functions
History function
– Storing of last 600 events (readout by optional TSE software)
Administrator code
– Factory set to 1-2-3-4-5-6 (please be sure to modify)
Power supply
– 4 × MIGNON LR6 AA ALKALINE
TSE BUSINESS 5000
Optical signaling
Optical signaling in the form of a LED is incorporated in the knob on the
inner side of the door. This LED informs you on the following:
– 1 × brief: lock has been opened
– 2 × brief: lock has been shut
– every 5 sec. 1 × brief: permanent opening activated
– 1 × brief, 1 × long, 2 sec. pause, repeated: lock in programming mode
– 5 × brief, 2 sec. pause, repeating at 20 sec. battery empty
Technical data
Blocking times
After 3 × wrong code is entered 1 minute,
then always 3 minutes
Display
Adjustable to 12 languages
Power supply
4 × MIGNON LR6 AA ALKALINE
Optimum ambient
-15 °C / +40 °C / Up to 95 % rel. air humidity
conditions
(noncondensing)
Allowed temperature range: -20 °C / +50 °C
As a result of extreme temperature changes, the
display can react slowly or darken.
TSE Set 5003 E-KEY
The electronic cylinder is operated by the radio controlled key E-Key. The
principle of its function is similar to that of a car locking system. The cylinder
can be controlled when the button is pressed once. The E-Key can be
programmed afterwards via a keypad or a TSE software. The radio range of
the E-Key is up to 3 m.
TSE 5003 E-KEY functions (as standard)
– Total number of users: up to 48
Optional locking media
– TSE 5103 E-KEY
– TSE 6101 Keypad PIN
– TSE 6102 Keypad FS (up to 24 fingerscans possible)
Time functions
– User timer (up to 24 different time windows)*
– Permanent timer (up to 16 different time windows)
* (only together with an appropriate TSE software)
History function
– Storing of last 600 events
(readout by optional TSE software)
Administrator code
The code is delivered on a separate sticker. Please store it carefully.
Attention: If the code gets lost it is impossible to change any
programmation or use any of the administrator functions.
Power supply cylinder
– 2 × MIGNON LR6 AA ALKALINE
Power supply E-Key
– 1 × CR 2032
Optical signaling
Optical signaling in the form of a LED is incorporated in the knob on the
inner side of the door. This LED informs you on the following:
– 1 × brief: lock has been opened
– 2 × brief: lock has been shut
– every 5 sec. 1 × brief: permanent opening activated
– 1 × brief, 1 × long, 2 sec. pause, repeated: lock in programming mode
– 5 × brief, 2 sec. pause, repeating at 20 sec. battery empty
Description of the menu functions
In the following the functions for the products TSE 5001 and TSE 5002
are described.

Menu functions

Menu code change
Changing the administrator code and the user codes
– Activate the keypad using the ON/Enter key
– Then press Function. "Menu/Code change..." is displayed
– Confirm your choice with ON/Enter. Now you can use the keys 1 or 2 to
scroll until the user, whose user code should be changed, is displayed
– Confirm with ON/Enter
– Enter the so far valid (previous) code and press ON/Enter
– Enter the new code confirm it with ON/Enter
– Repeat your entry and confirm it again with ON/Enter.
After a successful entry, "Code change completed!" is displayed
Menu Language/Sprache
Language setup
– Activate the keypad using the ON/Enter key
– Then press Function. "Menu/Code change" is displayed
– Scroll using the 2 key till reaching the appropriate menu item
– Confirm it with ON/Enter
– Scroll using the keys 1 or 2 until the required language is displayed
– Confirm it with ON/Enter
English | 8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tse set 5002 fingerscanTse set 5003 e-key

Table des Matières