CHIMNEY CONNECTION

Chimney installation must conform to both national and local code requirements. The chimney must be lined
EN
with one 2" (50.8mm) or 3" (76.2mm) diameter liner for intake and one 3" (76.2mm) diameter liner for exhaust.
The minimum and maximum vent lengths are 10ft (3m) and 35ft (10.7m) respectively. Recommended kits
come in 3 lengths:
1-2"Ø (25.4mm-50.8mm) & 1-3"Ø (25.4mm-76.2mm) DOUBLE PLY ALUMINUM LINER-INLET AND
2-3"Ø (50.8mm-76.2mm) DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
While the liners must be continuous from the appliance to the chimney cap, to
achieve the needed length, they may be coupled, using an approved coupler.
We recommend that exhaust vents that pass through unheated spaces,
such as tall exterior chimneys, be wrapped in a protective sleeve to minimize
condensation and reverse fl ow symptoms. See the "TROUBLESHOOTING"
section for details.
This appliance is approved for use with a 2" (51mm) liner for air intake and a 3"
(76mm) liner for exhaust. For best performance, however, it is recommended to
use two 3" (76mm) liners.
If a 2" (51mm) liner is used for the intake, it may be necessary to adjust the
primary air shutter.
A.
OUTSIDE: Slip the one end of a liner a
minimum of 2" (51mm) over the sleeve
of the air terminal. Secure using 3
screws. Then seal the joint and screw
heads with W573-0007 Mill-Pac (not
supplied). Repeat with the other liner.
NOTE: We recommend that the
other end of the exhaust liner be
marked to eliminate the exhaust
liner being connected to the intake
collar at the appliance.
B.
Gently stretch the liners to the required
lengths and insert into the chimney.
Trim and fi t the fl ashing plate to suit
the chimney termination. Place the air
terminal onto the top of the chimney.
Make weather tight by sealing with
caulking (not supplied). Fasten to the
chimney with screws and plugs (not
supplied).
C.
INSIDE: Remove the securing screw
from the front of the vent mounting
plate. Pull the vent mounting plate
only, back into the track, to the
front stop. Start the slider back into
position. Re-secure the screw. The
appliance may now be pushed into its
fi nal position inside the wood burning
appliance, and the screw tightened
until the slider has been pulled tight to
the front stop.
D.
Route the fl ex liners through the slider. Attach and secure the liners to the vent mounting plate using
the same procedure as before, ensuring that the marked exhaust liner is attached to the exhaust
collar.
W415-1365 / A / 07.28.16
EXHAUST & 2-3"Ø (50.8mm-76.2mm) TO 2"Ø (50.8mm) REDUCERS:
GDI-2320KT
GDI-2325KT
GDI-2335KT
GDI-320KT
GDI-325KT
GDI-335KT
VENT KIT 20FT (6.1m)
VENT KIT 25FT (7.6m)
VENT KIT 35FT (10.7m)
VENT KIT 20FT (6.1m)
VENT KIT 25 FT (7.6m
VENT KIT 35 FT (10.7m)
3" (76.2mm)
2" (50.8mm)
LINER
SLIDER
MILL-PAC
2" (50.8mm)
OVERLAP
MOUNTING
PLATE
REDUCER
INTAKE
FLASHING
PLATE
EXHAUST
MILL-PAC
INTAKE
LINER
CONNECTION
ILLUSTRATED WITH A 2"
(50.8mm) INTAKE LINER.
EXHAUST
SECURING
2" (50.8mm)
OVERLAP
SCREW