2.1

DIMENSIONS

2.2

MINIMUM CLEARANCE TO COMBUSTIBLES

This appliance must be recessed into a vented noncombustible wood-burning appliance (prefabricated or
masonry) only. The minimum appliance opening size in which the appliance is to be installed is:
HEIGHT 22" (559mm)
The minimum allowable chimney fl ue size is 6" (152mm) round.
The minimum distance, from the bottom of a combustible mantle projecting 3" (76mm) maximum from the
wall to the top of the louvre opening, is 12" (305mm).
23 1/8"
587mm
21 3/4"
5 1/4"
552mm
133mm
1 3/8"
13 3/4" 349mm
35mm
18 3/4" 476mm
WIDTH 28" (711mm)
DEPTH 18" (457mm)
27 1/2" 692mm
19 5/8" 499mm
13 3/4"
11 1/8"
349mm
283mm
30 1/16" 764mm
GAS INLET
W415-1365 / A / 07.28.16