Napoleon Oakville Serie Manuel D'installation
Masquer les pouces Voir aussi pour Oakville Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
f i r e - p a r t s . c o m
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
GDI3N / GDIG3N / GDIX3N
GDI3P / GDIG3P / GDIX3P
INSTALLATION MANUAL
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
ADD MANUAL TITLE
ADD PRODUCT IMAGE
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.33 AND ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
FRENCH PG. 47
Product Name / Code
Oakville™ Series
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
FOR INDOOR USE ONLY
NUMBER LABEL HERE
PLACE BARCODE LABEL ON THE
IF SEPARATE MANUALS, ADD "PLACE
OWNER'S MANUAL
W415-1802 / B / 02.07.19
ENGLISH
(GDIG3 illustrated)

Publicité

Table des Matières
loading

Sommaire des Matières pour Napoleon Oakville Serie

  • Page 1 OWNER’S MANUAL BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-1802 / B / 02.07.19...
  • Page 2: Safety Information

    safety information WARNING DANGER • This appliance is hot when operated and can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 patterns. safety information WARNING • Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this appliance. • This appliance must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.
  • Page 4: Table Des Matières

    table of contents general information adjustments rates and efficiencies pilot burner adjustment rating plate information venturi adjustment operating and lighting instructions flame characteristics shut-off valve maintenance dimensions annual maintenance minimum clearance to combustibles 10 care of glass installation planning care of plated parts levelling the appliance door glass replacement chimney connection...
  • Page 5: General Information

    standard checklist Installer: please fill out appliance checklist in the owner’s manual. 1.0 general information When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
  • Page 6: Rates And Efficiencies

    general information rates and efficiencies GDI3 Altitude (FT) 0 - 4500 0 - 4500 Max. Input (BTU/hr) 24,500 24,500 Max. Output (BTU/hr) 13,475 13,475 GDIG3 Altitude (FT) 0 - 4500 0 - 4500 Max. Input (BTU/hr) 24,000 24,000 Max. Output (BTU/hr) 14,808 14,808 f i r e - p a r t s .
  • Page 7 general information WARNING • Always light the pilot whether for the first time or if the gas supply has run out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. • Provide adequate ventilation. •...
  • Page 8: Rating Plate Information

    Minimum distance from bottom of a combustible mantel Distance minimale entre le dessous d’une tablette L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au projecting a maximum of 3” from the wall to the top of the décorative combustible, qui ressort un maximum de...
  • Page 9: Operating And Lighting Instructions

    general information operating and lighting instructions OPERATING INSTRUCTIONS / INSTRUCTIONS D’OPÉRATION FOR YOUR SAFETY READ BEFORE OPERATING / POUR VOTRE SÉCURITÉ LIRE AVANT DE FAIRE FONCTIONNER WARNING: ATTENTION: DO NOT TURN ON IF CHILDREN OR OTHER AT RISK NE PAS ALLUMER SI DES ENFANTS OU D’AUTRES INDIVIDUALS ARE NEAR THE APPLIANCE.
  • Page 10: Dimensions

    GDI3 GDIG3, GDIX3 general information A - 13 7/16 A - 13 13/16 [341mm] [376mm] dimensions B - 7 1/2 B - 6 7/8 [175mm] [175mm] front view right side view 20 15 " SAFETY BARRIER 531mm 3" 2 PLS 18 5 14 3 "...
  • Page 11: Installation Planning

    2.0 installation planning installation planning WARNING • Risk of fi re! Maintain specifi ed air space clearances to vent pipe and appliance. Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualifi ed person before installing the insert.
  • Page 12: Chimney Connection

    installation planning chimney connection Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and maximum vent lengths are 10' (3m) and 45' (14m) respectively.
  • Page 13: Gas Installation

    installation planning We recommend the following method of sealing off the damper area around the liner: Measure the throat of the appliance and mark this shape on a piece of 24 gauge sheet metal (flue cover). Cut a 6 3/4" (171mm) hole to lie directly below the appliance flue opening. Allow 2" of material for a flange on all sides and cut to these measurements.
  • Page 14: Finishing

    3.0 finishing finishing WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi ed dimension, as illustrated. •...
  • Page 15: Safety Barrier & Door Removal / Installation

    finishing safety barrier & door removal / installation WARNING • Glass may be hot. Do not touch glass until cooled. • If equipped with door latches that are part of a safety system, they must be properly engaged. Do not operate the appliance with latches disengaged.
  • Page 16: Log Placement

    Take the time to carefully position the glowing embers for a maximum glowing ef- “PHAZER™ logs [and glowing embers], exclusive to Napoleon/Continental, provide a unique and realistic fect. Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour glowing effect that is different in every installation.
  • Page 17 Burner Overview finishing Pilot Shield Notch Pilot Shield Notch Lower Media Tray Lower Media Tray (Logs #6, #7, and #8) (Logs #6, #7, and #8) Pilot Shield Notch Pilot Shield Notch Lower Media Tray Lower Media Tray (Logs #6, #7, and #8) (Logs #6, #7, and #8) Place log #1 snug against the back wall, Place the two holes in log #3 on A1 and A2.
  • Page 18 Notch Notch finishing Notches Notches Notches Notches Place log #7 along the centre of the lower Place log #8 along the right side of the lower PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. media tray. media tray. NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT.
  • Page 19: Log Placement For Gdix3

    Take the time to carefully position the glowing embers for a maximum glowing ef- “PHAZER™ logs [and glowing embers], exclusive to Napoleon/Continental, provide a unique and realistic fect. Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour glowing effect that is different in every installation.
  • Page 20 (Log #6 and #7) Burner Overview (Log #6 and #7) Grate Posts Grate Posts finishing Pilot Shield Notch Pilot Shield Notch Lower Media Tray Lower Media Tray (Log #6 and #7) (Log #6 and #7) Grate Posts Grate Posts Pilot Shield Notch Pilot Shield Notch Lower Media Tray Lower Media Tray...
  • Page 21 Notch Notch finishing Notches Notches Notches Notch Place log #7 along the right side of the lower PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. media tray. NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT. CONSISTENT THROUGHOUT. IF SPACE IS LEFT OVER, USE THIS BOX TO IF SPACE IS LEFT OVER, USE THIS BOX TO f i r e - p a r t s .
  • Page 22: Media Installation

    finishing media installation WARNING • Clean the glass media prior to installation. Before applying the cleaned glass, ensure that it is dry. • Do not change or substitute the glass media material provided with this appliance. If replacing, use only the replacement glass media available from your local authorized dealer / distributor.
  • Page 23: Charcoal Embers

    finishing charcoal embers WARNING • Do not block or close off the burner ports. Blocked ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. • When supplied, charcoal embers, charcoal lumps and vermiculite are not to be placed on the burner. Randomly place the charcoal embers along the front and sides of the log support in a realistic manner.
  • Page 24: Bracket Installation For Optional F45/60 Receiver (Gdi3)

    finishing 3.10 bracket installation for optional F45/60 receiver (GDI3) 1. Remove the safety barrier and glass door (see "safety barrier & door removal / installation" section). 2. Remove the 1 screw holding the bracket in place (Fig. 1). Lift the bracket up and out of the slots, lifting it through the opening between the firebox and the appliance's outer shell (Fig.
  • Page 25: Electrical Information

    4.0 electrical information wiring diagram (GDIG3 / GDIX3) WARNING • Do not wire 110 volts to the valve or wall switch. f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 26: Adjustments

    PSE THERMOCOUPLE 3/8” - 1/2” 5.0 adjustments adjustments (9.5mm - 12.7mm) Flame must envelop pilot burner adjustment upper 3/8" to 1/2" (12.7mm - 9.5mm) of thermocouple Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Check Pressure Readings: PILOT Inlet pressure can be checked by turning screw (A) counter-...
  • Page 27: Flame Characteristics

    adjustments flame characteristics It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustration provided. If any flames appear abnormal, call a service person. GDIG3 f i r e - p a r t s . c o m GDIX3 GDI3 W415-1802 / B / 02.07.19...
  • Page 28: Maintenance

    6.0 maintenance maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person.
  • Page 29: Annual Maintenance

    maintenance annual maintenance WARNING • Annual maintenance should be performed by a qualifi ed service technician • The fi rebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant gloves before conducting service. • Never vacuum hot embers. •...
  • Page 30: Care Of Plated Parts

    maintenance care of plated parts If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated surfaces before operating the appliance for the fi rst time. Use an ammonia-free or vinegar-based cleaner and a towel to clean.
  • Page 31: Night Light™ Replacement (Gdig3 / Gdix3)

    maintenance night light™ replacement (GDIG3 / GDIX3) Your appliance comes equipped with our “Night Light™”. The light has been pre-wired and is controlled from the remote control. If the lamp or lens needs to be replaced, follow the instruc- tions below. Fig.
  • Page 32: Valve Train Replacement

    maintenance valve train replacement Fig. 1 f i r e - p a r t s . c o m Remove safety barrier and glass door (see "safety barrier & door removal / installation" section). Remove media tray (see "media tray installation" section) and burners. Remove porcelain radiant panels (PRPs) or brick panels (if applicable).
  • Page 33: Replacement Parts

    7.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 34: Overview

    replacement parts f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 35: Right Side Access Plate Assembly

    replacement parts f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 36: Valve Train Assembly (Gdi3)

    replacement parts f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 37: Valve Train Assembly (Gdig3)

    replacement parts f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 38: Valve Train Assembly (Gdix3)

    replacement parts f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 39: Firebox Top Assembly

    replacement parts f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 40: Troubleshooting (Millivolt - Gdi3)

    8.0 troubleshooting (millivolt - GDI3) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 41 troubleshooting (millivolt - GDI3) symptom problem test solution Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button ignitor. PILOT Check if the push button ignitor needs tightening. BURNER Replace the wire if the wire insulation is broken or frayed.
  • Page 42: Troubleshooting (Electronic - Gdig3 / Gdix3)

    DEXEN EI troubleshooting (electronic - GDIG3 / GDIX3) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. ODS - MILLIVOLT • Turn off gas and electrical power before servicing the appliance. •...
  • Page 43 troubleshooting (electronic - GDIG3 / GDIX3) symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight. Verify noise with no spark at connections connections from pilot assembly are tight;...
  • Page 44 symptom problem test solution Wire connector pins are bent. Straighten pins. Motor is turning, Receiver batteries low. Replace batteries. Valve wiring is damaged. Replace valve. troubleshooting (electronic - GDIG3 / GDIX3) frequent beeping occurs. symptom problem test solution Lights or blower Control module switch in Verify ON/OFF switch is in the “I”...
  • Page 45: Warranty

    Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  • Page 46 - p a r t s . c o m 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686 napoleon.com...
  • Page 47 LE MANUEL DU PROPRIÉTAIRE LOGO BARCODE LABEL ON THE OWNER’S MANUAL” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleon.com • hearth@napoleon.com W415-1802 / B / 02.07.19...
  • Page 48 NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the consignés de sécurité hot viewing glass is provided with this appliance and shall be installed for the protection of children and other AVERTISSEMENT at-risk individuals.
  • Page 49 continue de s’éteindre, faire réparer. Garder propres le brûleur et le compartiment de contrôle. • Cet appareil ne devra être modifi é en aucun cas. • Ne laissez pas les ventilateurs souffl er directement sur l’appareil. Empêchez les courants d’air de modifi er consignés de sécurité...
  • Page 50 table de matières information générales réglages taux et efficacités réglage de la veilleuse information à propos de la plaque réglage du venturi d'homologation caractéristiques de la flamme instructions d'opération entretien et d'allumage entretien annuel soupape de fermeture soins de la vitre dimensions soins des pièces plaquées dégagements minimaux aux...
  • Page 51: Liste De Vérification

    liste de vérification Installateur, veuillez remplir la liste de contrôle de l'appareil dans le manuel du propriétaire. 1.0 information générales Lorsque l'appareil est installé à une altitude de plus de 4 500 pieds (1382m) et en l'absence de recommendations particulières de l'autorité compétente locale, l'indice certifié du débit à haute altitude devra être réduit au taux de 4% pour chaque 1 000 pi (305m) supplémentaire.
  • Page 52: Taux Et Efficacités

    information générales taux et efficacités GDI3 Altitude (PI) 0 - 4500 0 - 4500 Débit maximum (BTU/hr) 24 500 24 500 Rend. maximum (BTU/hr) 13 475 13 475 GDIG3 Altitude (PI) 0 - 4500 0 - 4500 Débit maximum (BTU/hr) 24 000 24 000 Rend.
  • Page 53 information générales AVERTISSEMENT • Allumez toujours la veilleuse, qu ce soit pour la première fois ou lorsque l'approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Prévoyez un accès suffisant pour entretenir et opérer l'appareil. • Assurez-vous d'une quantitée suffisante d'air de ventilation.
  • Page 54: Information À Propos De La Plaque D'homologation

    Minimum distance from bottom of a combustible mantel Distance minimale entre le dessous d’une tablette L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au projecting a maximum of 3” from the wall to the top of the décorative combustible, qui ressort un maximum de...
  • Page 55: Instructions D'opération Et D'allumage

    information générales instructions d'opération et d'allumage OPERATING INSTRUCTIONS / INSTRUCTIONS D’OPÉRATION FOR YOUR SAFETY READ BEFORE OPERATING / POUR VOTRE SÉCURITÉ LIRE AVANT DE FAIRE FONCTIONNER WARNING: ATTENTION: DO NOT TURN ON IF CHILDREN OR OTHER AT RISK NE PAS ALLUMER SI DES ENFANTS OU D’AUTRES INDIVIDUALS ARE NEAR THE APPLIANCE.
  • Page 56: Dimensions

    GDI3 GDIG3, GDIX3 general information A - 13 7/16 A - 13 13/16 [341mm] [376mm] dimensions B - 7 1/2 B - 6 7/8 [175mm] [175mm] vue de face vue de côté droite 20 15 " BARRIÈRE DE PROTECTION 531mm 3"...
  • Page 57: Planification De L'installation

    2.0 planification de l'installation installation planning AVERTISSEMENT • Risque d’incendie! Conservez les dégagements nécessaires au conduit d’évent et à l’appareil. Retirez les cendres de l’appareil de chauffage au bois. Assurez-vous que la cheminée et l’appareil de chauffage au bois sont propres et en bon état et qu’ils sont construits avec des matériaux incombustibles. Si nécessaire, faites faire les travaux de réparation par une personne qualifi ée avant d’installer l’encastré.
  • Page 58: Installation De La Cheminée

    planification de l'installation installation de la cheminée L’installation de la cheminée doit être conforme aux normes des codes nationaux et locaux. La cheminée doit être munie d'un conduit de 2" (51mm) ou 3" (76mm) de diamètre pour la prise d'air et d'un conduit de 3" (76mm) de diamètre pour l'évacuation.
  • Page 59: Branchement Du Gaz

    planification de l'installation note: Avant de fixer l'appareil en place, isolation à haute température devrait être emballé autour du linéaire dans la zone du registre pour empêcher le flux d'air d'entrer dans la cheminée de la maison. Ne pas le faire aura un impact négatif sur l'efficacité...
  • Page 60: Finitions

    3.0 finitions finishing AVERTISSEMENT • Risque d’incendie! • N’obstruez jamais l’ouverture sur le devant de l’appareil. • La façade de l’appareil doit être faite de matériaux incombustibles comme de la brique, du marbre, du granite, etc., à condition que ces matériaux ne se trouvent pas en deçà de la dimension spécifi ée tel qu’illustré. Comme alternative, vous pouvez utiliser le panneau de gypse comme fi nition pour votre appareil, voir les illustrations à...
  • Page 61: Enlèvement Et Installation De La

    finitions enlèvement et installation de la barrière de protection et la porte AVERTISSEMENT • La vitre peut être chaude. Ne touchez pas la vitre jusqu’à ce qu’elle ait refroidi. • Si équipé avec les loquets de porte qui font partie d’un dispositif de sécurité, ils doivent être adéquatement verrouillés.
  • Page 62: Disposition Des Bûches

    finitions disposition des bûches 3.3.1 disposition des bûches pour modèle GDI3 AVERTISSEMENT • Omettre de positionner les bûches conformément aux schémas ou omettre d’utiliser uniquement des bûches spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles.
  • Page 63 Burner Overview (Bûche #6, #7, et #8) (Bûche #6, #7, et #8) finitions Encoche de l’Écran de Veilleuse Encoche de l’Écran de Veilleuse Plateau à Média Plateau à Média Inférieur Inférieur (Bûche #6, #7, et #8) (Bûche #6, #7, et #8) Encoche de l’Écran de Veilleuse Encoche de l’Écran de Veilleuse Plateau à...
  • Page 64 Encoche Encoche Encoches Encoches finitions Encoches Encoches Placez la bûche #7 sur le centre de la plateau à Placez la bûche #8 sur le côté droite de la PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. média inférieure. plateau à média inférieure. NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT.
  • Page 65: Disposition Des Bûches Pour Modèle Gdix3

    finitions 3.3.2 disposition des bûches pour modèle GDIX3 AVERTISSEMENT • Omettre de positionner les bûches conformément aux schémas ou omettre d’utiliser uniquement des bûches spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. • Les bûches doivent être placées correctement à...
  • Page 66: Plateau À Média Plateau À Média Inférieure Inférieure

    Burner Overview Inférieure Tiges du Chenet Tiges du Chenet (Bûche #6 et #7) (Bûche #6 et #7) finitions Encoche de l’Écran de Veilleuse Encoche de l’Écran de Veilleuse Plateau à Média Plateau à Média Inférieure Inférieure Tiges du Chenet Tiges du Chenet (Bûche #6 et #7) (Bûche #6 et #7) Encoche de l’Écran de Veilleuse...
  • Page 67 Encoche Encoche finitions Encoches Encoches Encoches Encoche Placez la bûche #7 sur le côté droite de la PLACE TEXT BOX HERE. PLACE TEXT BOX HERE. plateau à média inférieure. NOTE: ENSURE NOMENCLATURE IS NOTE: ENSURE NOMENCLATURE IS CONSISTENT THROUGHOUT. CONSISTENT THROUGHOUT. IF SPACE IS LEFT OVER, USE THIS BOX TO IF SPACE IS LEFT OVER, USE THIS BOX TO f i r e - p a r t s .
  • Page 68: Installation Des Médias

    finitions installation des médias AVERTISSEMENT • Nettoyez les braises vitrifi ées avant d’installation. Assurez-vous qu’elles sont sèches avant de les disposer dans le plateau. • Ne changez pas ou ni substituez pas les braises vitrifi ées fournies avec cet appareil. En cas de remplacement, n’utilisez que les braises vitrifi ées de rechange disponibles chez votre détaillant autorisé.
  • Page 69: Braises Incandescentes

    finitions braises incandescentes AVERTISSEMENT • Obstruez pas ni fermer les orifi ces du brûleur. Le blocage des orifi ces du brûleur peut créer une fl amme irrégulière, des dépôts de carbone et un retard d’allumage. Déchirez les braises incandescentes en morceaux et placez une couche lâche sur le grillage du brûleur. Les braises devraient être déchirées très soigneusement en petits morceaux minces irréguliers, car seuls les côtés des fi bres exposées à...
  • Page 70: Enlèvement Du Récepteur

    finishing enlèvement du récepteur 1. Retirez le panneau d'accès droit de côté de l'appareil. 2. Retirez les 2 vis du bord intérieur (Fig. 2) et ouvrez la porte de commande. note: Si votre ouverture est trop petite, vous devrez peut-être retirez l'appareil légèrement. 3.
  • Page 71: Information Électrique

    4.0 information électrique schéma de câblage (GDIG3 / GDIX3) AVERTISSEMENT • Ne raccordez pas l’interrupteur mural ou la soupape de gaz à l’alimentation électrique (110 volts) f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 72: Réglage Du Venturi

    PSE THERMOCOUPLE 3/8” - 1/2” 3/8” - 1/2” adjustments 5.0 réglages (9.5mm - 12.7mm) (9.5mm - 12.7mm) Flame must envelop La flamme doit envelopper réglage de la veilleuse upper la thermocouple de 3/8" à 3/8" to 1/2" 1/2" (12.7mm - 9.5mm) of (9.5mm - 12.7mm) thermocouple Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale.
  • Page 73: Caractéristiques De La Flamme

    réglages caractéristiques de la flamme Il est important d'effectuer périodiquement une inspection visuelle de la flamme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des flammes paraissent anormales, contactez un techicien de service. GDIG3 f i r e - p a r t s . c o m GDIX3 GDI3 W415-1802 / B / 02.07.19...
  • Page 74: Entretien

    maintenance 6.0 entretien AVERTISSEMENT • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. • L’appareil peut être chaud. Attendez qu’il soit refroidi avant d’en faire l’entretien. • N’utilisez pas de produits abrasifs. • Ne peinture pas l’assemblage de la veilleuse. Cet appareil et son système d’évacuation devraient être inspectés avant la première utilisation et au moins une fois l’an par un technicien de service qualifi é.
  • Page 75: Entretien Annuel

    entretien entretien annuel AVERTISSEMENT • Le caisson devient trés chaud lors du fonctionnement. Laissez l’appareil se refroidir complétement ou portez des gants antichaleur avant d’effectuer l’entretien. • Ne jamais aspirer des braises qui sont chaudes. • Ne peinturez pas l’assemblage de la veilleuse. •...
  • Page 76: Soins Des Pièces Plaquées

    entretien soins des pièces plaquées Si l’appareil est muni de pièces plaquées, vous devez enlever toutes traces de doigts ou autres marques des surfaces plaquées avant d’allumer l’appareil pour la première fois. Utilisez les nettoyants sans ammoniaque ou à base de vinaigre. Si la surface plaquée n’est pas bien nettoyée avant le premier allumage de l’appareil, elle risque de rester marquée en permanence.
  • Page 77: Remplacement De La Lumière De Veille (Gdig3 / Gdix3)

    entretien remplacement de la lumière de veille (GDIG3 / GDIX3) Votre appareil est muni d'une lumière de veille. La lumière de veille est précâblée et est contrôlée par la télécom- mande. Si vous devez remplacer l'ampoule ou la lentille, suivez les instructions suivantes: Fig.
  • Page 78: Pièces De Rechange

    7.0 pièces de rechange AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 79 pièces de rechange f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 80 pièces de rechange f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 81 pièces de rechange f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 82 pièces de rechange f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 83 pièces de rechange f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 84 pièces de rechange f i r e - p a r t s . c o m W415-1802 / B / 02.07.19...
  • Page 85: Guide De Dépannage (Millivolt - Gdi3)

    8.0 guide de dépannage (millivolt - GDI3) AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 86 combustion. Vérifi ez si les joints d’étanchéité du porte ne sont pas brisés ni manquants et qu’ils sont étanches. Vérifi ez que les deux conduits d’évent ne soient pas troués et qu’ils soient bien scellés à tous les joints. guide de dépannage (millivolt - GDI3) Vérifi ez si l’élévation minimale par pied (mètre) est conforme pour toute évacuation horizontale.
  • Page 87 9.0 guide de dépannage (électronique - GDIG3/GDIX3) AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 88: Guide De Dépannage

    guide de dépannage (électronique - GDIG3 / GDIX3) symptôme problème solution La veilleuse ne s’allume Câblage: pénurie, connexion Vérifi ez qu’il n’y a pas de connexions desserrées du thermocouple ni sonde de fl amme. pas. Il y a du bruit mais desserrée (rectifi cation de la Vérifi ez l’interrupteur de bloc n’est pas endommagée ou trop serré.
  • Page 89: Électronique - Gdig3/Gdix3)

    Les piles du récepteur ou Remplacez les piles. fonctionne pas cor- aucune étincelle ou fl amme. (La note: Câble défecteux. Remplacer. fi ls sont courbeés. télécommmande sont faibles. Le télécommande est trop loin du Voir la section « schéma de câblage ». rectement.
  • Page 90: Garantie

    10.0 garantie Les produtits Napoléon sont fabriqués conformément aux normes strictes du Système de Gestion de la Qualité mondialement reconnu ISO 9001 : 2015. Les produits Napoléon sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi és qui sont fi ers de leur travail.
  • Page 91 11.0 notes f i r e - p a r t s . c o m 29.1 W415-1802 / B / 02.07.19...
  • Page 92 - p a r t s . c o m 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Téléphone: 1-866-820-8686...

Table des Matières