3.0 INSTALLATION

EN
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning
appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have
any repair work done by a qualifi ed person before installing the insert. Remove the existing appliance damper
or lock into an open position.
Using screws, attach the appliance warning tag
to the inside of the fi rebox of the appliance into
which the insert is being installed.
The sheet-metal parts of the appliance, in which
the gas appliance insert is to be installed, must
not be cut.
If the wood-burning factory-built appliance has
no gas access hole(s) provided, an access hole of 1½ inch (38.1mm) or less may be drilled through the lower
sides or bottom of the appliance in a proper workman like manner. This access hole must be plugged with non-
combustible insulation after the gas supply line has been installed.
Ensure that existing chimney cleanouts fi t properly.
The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the existing
appliance before installing the gas appliance insert.
Smoke shelves, shields and baffl es may be removed if attached by mechanical fasteners.
The ventilation openings in the existing appliance may be obstructed by the backer plates, aluminium trim etc.
but these parts are not to be applied so as to have an airtight seal.
3.1

LEVELLING THE APPLIANCE

Move the appliance close to its fi nal position inside the wood-burning appliance. This appliance is equipped
with 4 levelling screws located on the front and back on either side of the appliance base. Level using the
levelling screws to eliminate rocking or excessive noise when the fan is in operation. Once the appliance is
level, move it partially into place within the appliance to allow for all connections to be made. It is not practical
to level the appliance once it has been installed. Determine the required depth prior to installing the appliance
and adjust the four levelling screws accordingly.
3.2

CHIMNEY CONNECTION

Chimney installation must conform to both national and local code requirements. The chimney must be lined
with a 3" (76mm) or 4" (102mm) diameter approved liner. The minimum vent length is 10 feet (3m).
The liner must be continuous from the appliance to the chimney cap.
Remove the securing screw from the front of the dilution plate. Push
the dilution draft hood out of the securing clips and attach the liner
using 3 screws equally spaced. Pack insulation around the liner at
the damper area to prevent air fl ow from entering the chimney. Move
the insert into the centre of the woodburning appliance making
sure that the dilution draft hood inserts back into its securing clips.
Replace the securing screw to the front of the dilution plate.
W415-1362 / A / 09.15.16
WARNING
!
WARNING:
THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL
PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY HAVING
JURISDICTION.
ATTENTION:
CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT
COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU
TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT
ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES
AYANT JURIDICTION.
ADVERTENCIA:
ESTA CHIMENEA SE REMODELÓ PARA USARSE SOLO CON UNA
INSERCIÓN DE CHIMENEA A GAS Y NO PUEDE USARSE PARA QUEMAR MADERA NI COMBUSTIBLES
SÓLIDOS, A MENOS QUE SE HAYAN REEMPLAZADO TODAS LAS PIEZAS ORIGINALES, Y LA AUTORI-
DAD JURISDICCIONAL LA HAYA VUELTO A APROBAR.
SECURING CLIPS
W385-0199_B
68.4B
DILUTION
DRAFT HOOD
DILUTION PLATE