Chimney Connection - Napoleon XIR4-1N Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.2

CHIMNEY CONNECTION

Chimney installation must conform to both national and local code requirements. The chimney must be lined
with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and
maximum vent lengths are 10 feet (3m) and 35 feet (11m) respectively.
Recommended kits come in 3 lengths:
While the liners must be continuous from the appliance to the chimney cap,
to achieve the needed length, they may be coupled, using an approved
coupler and sealant.
We recommend that exhaust vents that pass through unheated spaces,
such as tall exterior chimneys, be wrapped in a protective sleeve to minimize
condensation and reverse flow symptoms. See "TROUBLESHOOTING"
section for details.
This appliance is approved for use with a 3" (76mm) exhaust and air intake.
OUTSIDE: Slip the one end of a liner a minimum of 2" (51mm)
A.
over the sleeve of the air terminal. Secure using 3 screws. Then
seal the joint and screw heads with high temperature sealant. Repeat with the other liner.
NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the
exhaust liner being connected to the intake collar at the appliance.
Gently stretch the liners to the
B.
required lengths and insert into
the chimney. Trim and fit the
flashing plate to suit the chimney
termination. Place the air terminal
onto the top of the chimney.
Make weather tight by sealing
with caulking (not supplied).
Fasten to the chimney with
screws and plugs (not supplied).
INSIDE: Remove the securing
C.
screw from the front of the vent
mounting plate. Pull the vent
mounting plate only, back into
the track, to the front stop. Start
the slider back into position.
Re-secure the screw. The
appliance may now be pushed
into its final position inside the
wood burning appliance, and the
screw tightened until the slider
has been pulled tight to the front
stop.
D.
Route the flex liners through the
slider. Attach and secure the liners to the vent mounting plate using the same procedure as before,
ensuring that the marked exhaust liner is attached to the exhaust collar.
2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
GDI-320KT
GDI-325KT
GDI-335KT
HIGH TEMP
SEALANT
2" (50.8mm)
OVERLAP
VENT KIT 20FT (6m)
VENT KIT 25 FT (7m)
VENT KIT 35 FT (11m)
3" (76.2mm)
LINERS
SLIDER
MOUNTING
PLATE
EXHAUST
FLASHING
PLATE
2" (50.8mm)
OVERLAP
EXHAUST
MILL-PAC
INTAKE
VENT MOUNT
ASSEMBLY
INTAKE
SECURING
SCREW
W415-1344 / A / 12.14.16
9
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Xir4-1p

Table des Matières