7. ADVANCED PARAMETER SETTING
7.1. Navigating in parameter setting mode
Buttons
OK
• Press twice to access the settings menu
• Press once to confirm:
+ OR -
Navigating the parameter list
Modifying the value of a setting
+ AND -
Exiting the settings menu
7.2. List of settings (menus and sub-menus)
In the table, the value in bold type corresponds to the default value.
Menu
Sub-menu
5 to 300 (5) Maximum operating time when opening (in seconds)
5 to 300 (5) Maximum operating time when closing (in seconds)
0 to 180
(40)
0 to 99 (0)
0 to 99 (0)
10 to 50
(20)
1 to 99 (41) Force exerted by the gate when opening (%)
1 to 99 (41) Force exerted by the gate when closing (%)
1 to 99 (75) Force exerted by the gate when slowing down during opening (%)
1 to 99 (75) Force exerted by the gate when slowing down during closing (%)
0 to 10 (0)
0
1
0
1
0
7
- the parameter selection
- the parameter value
Val.
Adjusted automatically during auto-programming
Adjusted automatically during auto-programming
Automatic closing timeout
Deceleration distance when opening expressed as a percentage of the total travel (%)
If it is less than 50 cm, it will automatically be adjusted during auto-programming
Deceleration distance when closing expressed as a percentage of the total travel (%)
If it is less than 50 cm, it will automatically be adjusted during auto-programming
Pedestrian opening distance expressed as a percentage of the total travel (%)
Adjusted automatically during auto-programming
Adjusted automatically during auto-programming
Adjusted automatically during auto-programming
Adjusted automatically during auto-programming
Braking during slowing phase (%)
Automatic closing not activated
Automatic closing activated
Quick closing not activated
Quick closing activated: closing 3 s a er the cells are cleared without waiting for the end of the automatic
closing timeout configured
Sequential
Each press on the remote control causes the motor to move (initial
position: gate closed) as per the following cycle: open, stop, close,
stop, open, etc.
Sequential + automatic timed close
Operation in automatic closing mode is only authorised if photoelec-
tric cells with autotest function are installed (see Fig. 19)
In sequential mode with automatic timed close:
• the gate closes automatically a er the timeout programmed in the
/
• pressing the button on the remote control interrupts the move-
ment in progress then the gate closes automatically a er the
timeout programmed
Function
Description
menu
ELIXO 2000 230V RTS
Warning
If one of the settings is modified,
the installer must check that
obstacle detection complies with
Appendix A of standard EN 12
453. If necessary, install a safety
edge and check that compliance
is obtained.
Failure to follow this instruction
may result in serious injury, e.g.
due to crushing by the gate.
With following
parameter
setting:
= 0
= 0
= 0
With following
parameter
setting:
= 1
= 0
= 0